2014-09-062014-09-062014-05-22PEREIRA, Ronivon Soares; GOMES, Orlano Ferreira. Ligações em estruturas de aço utilizando emendas com parafusos de alta resistência solicitadas na flexão simples. Revista Eletrônica de Engenharia Civil, Goiânia, v. 8, n. 2, p. 27-42, 2014. Disponível em: < http://www.revistas.ufg.br/index.php/reec/article/view/27185>.http://repositorio.bc.ufg.br/handle/ri/4113v. 8, n. 2, p. 27-42, abr./jun. 2014.Structure is designed to have satisfactory performance given the quality standards and requirements in the construction of which designers need. Increasingly, large metal structures are developing in this competitive market, where performance and quality of the project depend on manufacturing processes of materials, assembly, inspection and maintenance. The metal structures, especially those of type I profiles of parallel laminated tabs depend on the quality control in your bolted splices. This article aims to analyze the bearing capacity of steel beams supported by profiles consist of type I rolled parallel flanges with two axes of symmetry, being endowed with seams with high strength bolts type ASTM A325, diameter 19 mm, being requested by models of simple bending efforts.porAcesso abertoAçoParafusosEstruturas de açoFlexão simplesSteelBoltsSteel structuresSimple bendingLigações em estruturas de aço utilizando emendas com parafusos de alta resistência solicitadas na flexão simplesConnections in steel structures using emendations with high strength screws requested in simple bendingArtigoDOI: 10.5216/reec.v8i2.27185)