Tubos de látex: esterilidade pós-reprocessamento em vapor saturado sob pressão

dc.creatorTipple, Anaclara Ferreira Veiga
dc.creatorPimenta, Fabiana Cristina
dc.date.accessioned2010-04-29T12:37:50Z
dc.date.available2010-04-29T12:37:50Z
dc.date.issued2009-05-25
dc.descriptionv. 11, n. 2, p. 280-285, abr./jun. 2009.en
dc.description.abstractEntre os artigos odonto-médico-hospitalares, os tubulares merecem atenção especial para o reprocessamento pela dificuldade de limpeza de seu lúmen, que pode permitir acúmulo de matéria orgânica e formação de biofilme. Com o objetivo de avaliar a esterilidade dos tubos de látex submetidos ao processo de esterilização em autoclave a vapor em um hospital de Goiânia-GO foram analisados 30 tubos pós-reprocessamento. Realizaram-se cortes transversais de 01 cm em dois segmentos dos tubos: extremidade (E) e metade (M) que foram inoculados em caldo BHI (Brain Heart Infusion) e incubados a 37o C por 20 dias. Amostras com turvação visível foram semeadas em ágar sangue de carneiro para isolamento microbiano. As colônias desenvolvidas foram caracterizadas pela morfologia e por testes bioquímicos. Houve desenvolvimento microbiano em 05 (16,7%) amostras, sendo 03 (10%) segmentos M e 02 (6,7%) seguimentos E. Os microrganismos contaminantes foram identificados como bacilos Gram-positivo (BGP), estafilococos coagulase negativa e positiva (ECN, ECP). Múltiplos reprocessamentos desses artigos facilita o desgaste, colabamento, ressecamento, formação de rachaduras, o que favorece a retenção de microrganismos. De acordo com estes resultados, conclui-se que tubos de látex reprocessados em autoclave a vapor podem representar riscos aos usuários. _______________________________________________________________________________________________________________________ ABSTRACT _______________________________________________________________________________________________________________________ Among the dentistry and medical articles the tubular dispositive requires special attention to the reprocessing due to lumen cleaning difficulty, and also organic material retention allowing biofilm establishment. The aim of this study was to evaluate the sterility of 30 latex pipes submitted to the sterilization process by vapor in autoclave" in a hospital of Goiania-GO. The latex pipe was cut transversely in 2 pieces of 1cm, one at the extreme(E) and middle (M).They were inoculated in BHI (Brain Heart Infusion) and incubated at 37ºC for 20 days. The samples with positive growth were seeded on sheep blood agar for microbial isolation. The colonies were characterized by morphology and biochemical tests. Microorganisms were detected in 5 latex pipes samples (16.7%), from these, 3 samples (10%) obtained from middle pieces, and 2 from extreme pieces (6.7%). The contaminants were identified as Gram-positive bacilli (BGP), coagulase negative staphylococcus (ECN), and coagulase positive staphylococcus (ECP). Multiple reprocessed of these articles are distinguished what facilitates to consuming, collapse, drying, formation of cracks, and microorganisms retention. According to our results, the latex pipes reprocess using vapor in autoclave might be a risk to the users.en
dc.identifier.citationTIPLLE, Anaclara Ferreira Veiga; PIMENTA, Fabiana Cristina. Tubos de látex: esterilidade pós-reprocessamento em vapor saturado sob pressão. Revista Eletrônica de Enfermagem, Goiânia, v. 11, n. 2, p. 280-285, abr./jun. 2009. Disponível em:<http://www.fen.ufg.br/revista/v11/n2/v11n2a07.htm.>.en
dc.identifier.issn1518-1944
dc.identifier.urihttp://repositorio.bc.ufg.br/handle/ri/63
dc.language.isopt_BRen
dc.location.countryBRAen
dc.rightsOpen Accessen
dc.subject.keywordEsterilizaçãoen
dc.subject.keywordControle de qualidadeen
dc.subject.keywordInfecção hospitalaren
dc.titleTubos de látex: esterilidade pós-reprocessamento em vapor saturado sob pressãoen
dc.title.alternativeLatex pipes: sterility of the subjected to the process of sterilization through vapor in "autoclave"en
dc.title.alternativeTubos del látex: esterilidad pós-reprocesamento a través del vapor en “autoclave"en
dc.typeArtigoen

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
tubos_latex_v11n2a07.pdf
Tamanho:
72.52 KB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.81 KB
Formato:
Item-specific license agreed upon to submission
Descrição: