Análise de desempenho térmico e consumo de energia estudo de caso em hotelaria

Carregando...
Imagem de Miniatura

Data

2008-10-03

Título da Revista

ISSN da Revista

Título de Volume

Editor

Universidade Federal de Goiás

Resumo

This study, concerns the area of Recursos Hídricos e Saneamento Ambiental, and investigates how internal and external temperature effects the comfort in a hotel building , which has multiple functions and different levels of users. It is aimed to check the thermal performances, considering the surrondings , the activities of the users, their preferences and possibilities of heat acclimatization, the final use and habits of consumption of electric energy. As a theoretical framework for this task, it uses by choice bioclimatic architecture , an area that concerns the construction focused on greater energy efficiency and comfort. The verification of environmental suitability offered in different environments evaluated, took advantage of the studies of Fanger (1970), suggested by ISO -7730 (1995), ISO-9920 (1995) and ASHRAE (1992), as well as questionnaires answered by users of the building. Thus proceeded to study the urban characterization of the city of Rio Quente; the survey and selection of the building for the Case Study; selection of sites for measurement, data collection, analysis and comparison of results with Thermal Comfort indexes suggested by Fanger (1970). The environments selected followed the criteria for critical positioning in line with the direction of longer periods of solar direct impact on the facades, the burden of occupation, the direct and ventilation equipment. This case study used five sets of comfort measuring devices, to obtain Dry Bulb Temperature (DBT) and Radiant Thermal Load (RTL) and Air Relative Humidity (ARH) . Data was collected internally and externally from the building in aim to verify the behaviour of this construction , and after the external data was compared to the data provided by the Plataforma de Coleta de Dados (PCD) of Serra de Caldas, for checking the quality of data available for designers. The analysis showed the best confort perfomance in the Accomodation Areas where, despite no possibility of acclimatization due to the short periods of stay , there was a significant response from the guests . The Common Area also showed satisfactory results in terms of this group of users, due to the characteristics of their clothing and metabolism which in itself merits this project. The worst performance took place in the Services Sector, which presented no conditions of comfort and stayed outside of Fanger´s scale during most of the day, subjecting users to discomfort, this shows that this group of users,workers, are not considered in the early stages of the project.

Descrição

Citação

PINTO, Maryana de Souza. Building Eficiency Analysis - hotelery studie. 2008. 113 f. Dissertação (Mestrado em Engenharias) - Universidade Federal de Goiás, Goiânia, 2008.