2016-04-042015-10-16VIRGENS, J. P. Análise experimental de pilares de concreto armado, com carga excêntrica, reforçados com chumbadores e concreto autoadensável (CAA). 2015. 266 f. Dissertação (Mestrado em Engenharia Civil) - Universidade Federal de Goiás, Goiânia, 2015.http://repositorio.bc.ufg.br/tede/handle/tede/5403This paper presents the experimental study of reinforcement concrete columns reinforced with wedge bolts and a 35 mm self compacting concrete jacket at the most compressed face. Nine columns with a 2000 mm height subjected to flexure and bending with initial eccentricity of 60 mm, named as: original column (Po) with a cross section of 120 mm x 250 mm; reference column (Pref) with a cross section of 155 mm x 250 mm and seven columns with a initial cross section of 120 mm x 250 mm, and later reinforced by the addition of 35 mm reinforcing layer, and various configurations of wedge bolts at its most compressed face. Except for the original column (Po), the columns were submitted to a 42.5 mm load eccentricity due to the attached concrete layer at the compressed face. Although failure of the wedge bolts did not accour, it was not possible to prevent detachment of the reinforcing layer. The results indicate that it is possible to structural rehabilitate reinforce concrete columns with the use of the strengthening methodology used in this research, resulting in average load capacity gains of 3,71 times compared to original column load (Po).application/pdfAcesso AbertoPilarReforço estruturalConcreto autoadensávelParafusos chumbadoresColumnStructural reinforcementSelf compacting concreteWedge boltsENGENHARIA CIVIL::ESTRUTURASAnálise experimental de pilares de concreto armado, com carga excêntrica, reforçados com chumbadores e concreto autoadensável (CAA)Experimental analysis of reinforced concrete columns, under eccentric load, reinforced with wedge bolts and self compacting concrete (SCC)Dissertação