Use este identificador para citar ou linkar para este item:
http://repositorio.bc.ufg.br/tede/handle/tede/4143
Registro completo de metadados
Campo DC | Valor | Idioma |
---|---|---|
dc.creator | Lemes, Sandra Stival dos Santos | - |
dc.creator.Lattes | http://lattes.cnpq.br/8801248657283316 | eng |
dc.contributor.advisor1 | Lenza, Marcos Augusto | - |
dc.contributor.advisor1Lattes | http://lattes.cnpq.br/0734929669869820 | eng |
dc.contributor.advisor-co1 | Souza, João Batista de | - |
dc.contributor.referee1 | Lenza, Marcos Augusto | - |
dc.contributor.referee2 | Janson, Guilherme dos Reis Pereira | - |
dc.contributor.referee3 | Dias, Fátima Ribeiro | - |
dc.date.accessioned | 2015-02-12T19:33:13Z | - |
dc.date.issued | 2008-02-25 | - |
dc.identifier.citation | LEMES, S. S. S. Avaliação da citotoxicidade dos extratos da corrosão de mini-implantes ortodônticos de TI- 6AL-4V após imersão em saliva artificial fluoretada por 30, 90 ou 180 dias. 2008. 65 f. Dissertação (Mestrado em Odontologia) - Universidade Federal de Goiás, Goiânia, 2008. | eng |
dc.identifier.uri | http://repositorio.bc.ufg.br/tede/handle/tede/4143 | - |
dc.description.resumo | As ligas metálicas utilizadas na terapia ortodôntica estão sujeitas ao processo de corrosão na cavidade bucal. Mini-implantes de Ti-6Al-4V utilizados em ortodontia tornou-se um ótimo recurso de ancoragem intrabucal, contudo, sua resistência à corrosão na presença de flúor é pouco conhecida. O objetivo deste trabalho in vitro foi avaliar a citotoxicidade dos extratos da corrosão de mini-implantes ortodônticos de Ti-6Al-4V de três diferentes marcas comerciais, quando expostos em saliva artificial fluoretada contendo 200 µg/L de fluoreto de sódio, por 30, 90 ou 180 dias. A citotoxicidade dos extratos foi avaliada, em cultura de células L929, por meio da análise do ensaio do MTT (3-{4,5-dimetiltiazol-2il} -2,5-difenil brometo de tetrazólio). Os extratos não foram citotóxicos e o ensaio de citotoxicidade revelou não haver diferenças entre as amostras, demonstrando um comportamento semelhante para os extratos provenientes dos mini-implantes imersos em saliva nos três períodos avaliados. A análise qualitativa, por meio do MEV não revelou áreas com características de corrosão propriamente dita. Os resultados demonstraram que os mini-implantes testados apresentam alta resistência à corrosão e sugerem que são biocompatíveis. | eng |
dc.description.abstract | The alloys used in the orthodontic therapy are subject to the corrosion process in the oral environment. Orthodontic mini-implants Ti-6Al-4V are an excellent source for intraoral anchorage; however, their corrosion resistance in the presence of fluoride is currently unknown. The purpose of this in vitro study was to evaluate the cytotoxic effects of the corrosion extracts of mini-implants Ti-6Al-4V from three different manufacturers when exposed to 200 g/L of sodium fluoride containing artificial saliva for 30, 90 or 180 days. The cytotoxic effects of their corrosion products on L929 cell culture was evaluated by MTT (3- [4,5-dimethylthiazol-2-yl]2,5-diphenyltetrazolium bromide) assay, for cell metabolism and proliferation. The extracts were not cytotoxic and the cytotoxicity assay demonstrated a similar behavior for the samples immersed in artificial saliva in the three evaluated periods. The qualitative analysis, through SEM did not show characteristics of corrosion. The results indicated that the mini-implants tested presented a high corrosion resistance and biocompatibility. | eng |
dc.description.provenance | Submitted by Erika Demachki (erikademachki@gmail.com) on 2015-02-12T19:32:51Z No. of bitstreams: 2 Dissertação - Sandra Stival dos Santos Lemes - 2008.pdf: 7357278 bytes, checksum: 783dfa4660c8b2298763eff63fd6a65b (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) | eng |
dc.description.provenance | Approved for entry into archive by Erika Demachki (erikademachki@gmail.com) on 2015-02-12T19:33:13Z (GMT) No. of bitstreams: 2 Dissertação - Sandra Stival dos Santos Lemes - 2008.pdf: 7357278 bytes, checksum: 783dfa4660c8b2298763eff63fd6a65b (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) | eng |
dc.description.provenance | Made available in DSpace on 2015-02-12T19:33:13Z (GMT). No. of bitstreams: 2 Dissertação - Sandra Stival dos Santos Lemes - 2008.pdf: 7357278 bytes, checksum: 783dfa4660c8b2298763eff63fd6a65b (MD5) license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Previous issue date: 2008-02-25 | eng |
dc.format | application/pdf | * |
dc.thumbnail.url | http://repositorio.bc.ufg.br/tede/retrieve/16811/Disserta%c3%a7%c3%a3o%20-%20Sandra%20Stival%20dos%20Santos%20Lemes%20-%202008.pdf.jpg | * |
dc.language | por | eng |
dc.publisher | Universidade Federal de Goiás | eng |
dc.publisher.department | Faculdade de Odontologia - FO (RG) | eng |
dc.publisher.country | Brasil | eng |
dc.publisher.initials | UFG | eng |
dc.publisher.program | Programa de Pós-graduação em Odontologia (FO) | eng |
dc.rights | Acesso Aberto | - |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | - |
dc.subject | Implante dentário endoósseo | por |
dc.subject | Flúor | por |
dc.subject | Corrosão | por |
dc.subject | Citotoxicidade | por |
dc.subject | Endosseous dental implantation | eng |
dc.subject | Fluoride | eng |
dc.subject | Corrosion | eng |
dc.subject | Cytotoxicity | eng |
dc.subject.cnpq | ODONTOLOGIA::CLINICA ODONTOLOGICA | eng |
dc.title | Avaliação da citotoxicidade dos extratos da corrosão de mini-implantes ortodônticos de TI- 6AL-4V após imersão em saliva artificial fluoretada por 30, 90 ou 180 dias | eng |
dc.type | Dissertação | eng |
Aparece nas coleções: | Mestrado em Odontologia (FO) |
Arquivos associados a este item:
Arquivo | Descrição | Tamanho | Formato | |
---|---|---|---|---|
Dissertação - Sandra Stival dos Santos Lemes - 2008.pdf | 7,18 MB | Adobe PDF | ![]() Baixar/Abrir |
Este item está licenciada sob uma Licença Creative Commons