Abstract: Acceptable therapeutic protocol in dentistry depends on the outcomes obtained with follow up. Operative procedural errors (OPE) may occur and they represent risk factors able to compromise a tooth or a dental implant. The aim of this study was to detect the OPE in endodontically treated teeth and dental implants, using cone beam computed tomography (CBCT). Eight hundred and sixteen CBCT exams were performed between January 2009 and October 2010, and only those which presented endodontically treated teeth and/ or dental implants were selected. The sample was as follows: 195 CBCT exams (n=200 teeth and 200 dental implants), 72 male, 123 female, with mean age of 51 years. In endodontically treated teeth, OPE included underfilling, overfilling, and root perforation; OPE in dental implants were thread exposures, contact with anatomical structures, and contact with adjacent teeth. Kolmogorov-Smirnov test was used for statistical analysis, with significance level set at α=0.05. Underfilling, overfilling, and root perforations were detected in 33.5%, 8% and 4.5% of the teeth, respectively. Dental implants with thread exposures, contact with important anatomical structures and contact with adjacent teeth were seen in 37.5%, 13% and 6.5% of the cases, respectively. OPE were detected in endodontically treated teeth and dental implants, and underfilling and thread exposures were the most frequent occurrences, respectively.
Palavras-chave: Endodontic failure
Diagnostic imaging
Dental implant failure
Cone beam computed tomography
País: Brasil
Unidade acadêmica: Faculdade de Odontologia - FO (RG)
Citação: SILVA, Julio Almeida et al. Three-dimensional image contribution for evaluation of operative procedural errors in endodontic therapy and dental implants. Brazilian Dental Journal, Ribeirão Preto, v. 23, n. 2, p. 127-134, 2012.
Tipo de acesso: Acesso Aberto
Identificador do documento: 10.1590/S0103-64402012000200007
Identificador do documento: 10.1590/S0103-64402012000200007
URI: http://repositorio.bc.ufg.br/handle/ri/16351
Data de publicação: 2012
Aparece nas coleções:FM - Artigos publicados em periódicos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Artigo - Julio Almeida Silva - 2012.pdf1,31 MBAdobe PDFThumbnail
Baixar/Abrir


Este item está licenciada sob uma Licença Creative Commons Creative Commons