Punção em lajes cogumelo de concreto armado ‐ retangularidade dos pilares
Carregando...
Data
Título da Revista
ISSN da Revista
Título de Volume
Editor
Ricardo Prado Abreu Reis
Resumo
Eight reinforced concrete flat slabs were tested. Slabs were 1800mm square
and 130mm thick and were submitted to concentric loading. The objective of this study
was to investigate the influence of column rectangularity coefficient. The relationship
between the column cross section dimensions (cmáx/cmín) varyied between 1 and 4 with a
constant perimeter equal to 1000mm. Results presented and analyzed include ultimate
loads and failure types, modes of rupture, vertical displacements, cracking and
deformations of steel and concrete. Comparisons with codes and with results obtained by
other researchers are also presented. The results indicate that as the rectangularity
coefficient increases, punching shear resistance decreases for constant perimeter column
flat slabs. This suggests that punching shear has to be considered especially in regions
close to column corners, where there is a larger concentration of shear forces. A proposal
for an inclusion of the rectangularity parameter (cmáx/cmín) in expressions for calculation
punching shear resistance of ACI (2002), CEB‐FIP (1991), EC2 (2001) and NBR‐6118 (2003)
codes is presented.
Descrição
Palavras-chave
Citação
COSTA, Valéria Conceição Mouro; OLIVEIRA, Diorgenes Carvalho de; GOMES, Ronaldo Barros; GUIMARÃES, Gilson Natal. Punção em lajes cogumelo de concreto armado ‐ retangularidade dos pilares. Revista Eletrônica de Engenharia Civil, Goiânia, v. 5, n. 1, jul./set. 2012. Disponível em: <https://www.revistas.ufg.br/reec/article/view/19869/12082>.