Incidência de opacificação de cápsula posterior em pacientes submetidos à facoemulsificação e implante de lentes intra-oculares acrílicas hidrofílicas expansíveis
Carregando...
Data
2006
Título da Revista
ISSN da Revista
Título de Volume
Editor
Resumo
Purpose: To evaluate prospectively the results of expandable
acrylic intraocular lenses in patients submitted to phacoemul-
sification as regard posterior capsule opacification. Methods:
The study group consisted of 830 patients, 1,200 eyes that
underwent phacoemulsification from 1998 to 2002, by the
same surgeon, using the same technique but with different
diameters of capsulorrhexis, with expandable hydrophilic
acrylic intraocular lens implantation. The mean follow-up was
2.4 years, ranging from 6 months to 4 years. Results: The total
number of posterior capsule opacification was 54 cases. Con-
clusions: The incidence of posterior capsule opacification
was 4.6% in these patients.
Descrição
Palavras-chave
Implante de lente intra-ocular, Capsulorrexe, Lentes de contato hidrofílicas, Cápsula do cristalino, Acuidade visual, Facoemulsificação, Lens implantation, intraocular, Capsulorrhexis, Contact lenses, hydrophilic, Phacoemulsification, Lens capsule, crystalline, Visual acuity
Citação
MEDEIROS, Hilton Arcoverde Gonçalves de; ÁVILA, Marcos; SANTOS, Procopio Miguel dos. Incidência de opacificação de cápsula posteriorem pacientes submetidos à facoemulsificação e implante de lentes intra-oculares acrílicas hidrofílicas expansíveis. Arquivos Brasileiros de Oftalmologia, São Paulo, v. 69, n. 3, p. 371-375, 2006.