Use este identificador para citar ou linkar para este item: http://repositorio.bc.ufg.br/handle/ri/18069
Tipo do documento: Artigo
Título: Fatores associados ao material insulficiente em punção aspitativa por agulha fina nos módulos sólidos da mama
Título(s) alternativo(s): Factors related to insufficient material in fine needle aspiration cytology of solid breast tumors
Autor: Freitas Júnior, Ruffo de
Paulinelli, Régis Resende
Moreira, Marise Amaral Rebouças
Resumo: Objetivo: analisar alguns fatores que possam estar associados à ocorrência de material insuficiente nos aspirados da punção aspirativa por agulha fina (PAAF). Pacientes e Métodos: foram estudadas 351 citologias de pacientes com nódulos sólidos da mama, submetidas a PAAF, como parte de sua investigação diagnóstica. As lâminas foram analisadas por um único citologista, que classificou os esfregaços como malignos, suspeitos, benignos ou material insuficiente para diagnóstico. Foram avaliados a idade da paciente, o tamanho do tumor, o estádio clínico, o Serviço, o dispositivo utilizado na punção e o tipo de lesão puncionada, de acordo com a histologia. A significância de cada variável em relação ao material insuficiente foi testada pelo χ 2 . Resultados: houve 67 esfregaços classificados como material insuficiente (19%). O tipo de dispositivo utilizado, o tamanho do tumor, o Serviço e o estádio clínico das lesões não se relacionaram à quantidade de material suficiente ou insuficiente. A idade da paciente e o tipo histológico influenciaram a taxa de material insuficiente, sendo que as pacientes abaixo de 50 anos tiveram uma taxa de 12%, comparada a 30% daquelas acima de 50 anos (p<0,03). Quanto à histologia, nas pacientes com alterações funcionais benignas da mama, a taxa de material insuficiente foi de 30%, seguida daquelas com carcinoma ductal infiltrante, 20%, e, no fibroadenoma, 12% (p<0,02). Conclusão: esse estudo mostrou uma taxa de material insuficiente relativamente alta (19%), a qual foi influenciada pela idade da paciente e pelo tipo histológico da lesão.
Abstract: Purpose: to analyze the factors that may be related to insufficient material in fine needle aspiration cytology (FNAC). Patients and Methods: a total of 351 FNAC of patients with solid breast tumors were studied in a random way: 180 (51%) by Cameco’s pistol holder and 171 (49%) by the auto-vacuum device. All smears were analyzed by only one cytopathologist, and they were described as malignant, suspicious, benign or insufficient for diagnosis. The significance of each variable was tested by the χ 2 test. Results: among the 351 cases analyzed, we found 67 (19%) of insufficient material. The device used (pistol or auto- vacuum), the size of the tumor and the clinical stage of the lesions were not related to the frequency of sufficient and insufficient material. The age of the patient and the histological type of the tumor were related to the rate of insufficient material. Patients younger than 50 had a 12% rate of insufficient material, compared to 30 above 50 (p<0.03). The patients with fibroadenosis had a rate of 30%, those with ductal carcinoma, 20%, and those with fibroadenoma 12% (p<0.02). Conclusion: the present study showed a relatively high rate of insufficient material (19%), which was influenced by the age of the patient and the histological type of the biopsied breast lesion.
Palavras-chave: Mama: câncer
Punção aspirativa
Mama: doenças benignas
Breast: neoplasms
Breast: benign diseases
Fine needle biopsy
Cytology
País: Brasil
Unidade acadêmica: Faculdade de Medicina - FM (RG)
Citação: FREITAS JUNIOR, Ruffo de; PAULINELLI, Regis Resende; MOREIRA, Marise Amaral Rebouças. Fatores associados ao material insulficiente em punção aspitativa por agulha fina nos módulos sólidos da mama. Revista Brasileira de Ginecologia e Obstetrícia, Rio de Janeiro, v. 23, n. 10, p. 635-639, 2001.
Tipo de acesso: Acesso Aberto
Identificador do documento: 10.1590/S0100-72032001001000004
Identificador do documento: 10.1590/S0100-72032001001000004
URI: http://repositorio.bc.ufg.br/handle/ri/18069
Data de publicação: 2001
Aparece nas coleções:FM - Artigos publicados em periódicos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Artigo - Ruffo de Freitas Júnior - 2001.pdf193,81 kBAdobe PDFThumbnail
Baixar/Abrir


Este item está licenciada sob uma Licença Creative Commons Creative Commons