Avaliação do desempenho da filtração em múltiplas etapas (FiME) no tratamento da água do Ribeirão Sozinha em Goianápolis - Estado de Goiás.

Carregando...
Imagem de Miniatura

Data

2009-08-17

Título da Revista

ISSN da Revista

Título de Volume

Editor

Universidade Federal de Goiás

Resumo

This work presents an evaluation of the performance of a multi-stage filtration system (FiME) in pilot-plant scale to treat surface water from the Ribeirão Sozinha stream which supplies the city of Goianápolis-GO, Brazil. The arrangement of the installation used in this study consisted of a dynamic roughing filter (PFD), a up-flow roughing filter (PFA) and two slow sand filters, being one with sand (FLA) and the other with sand and granular activated carbon (FLACAG). The filtration rates varied from 24 to 48 m3/m2.d in the PFD, 12 to 18 m3/m2.d in the PFA, and 3 to 4 m3/m2.d in the FLA and FLACAG. The performance of each unit was evaluated for removal of color, turbidity, total iron, suspended solids, oxygen consumption, total coliforms and E.coli, and the development of headloss. Results showed that the PFD and PFA are important units in the preparation of affluent water to the slow sand filters, allowing relatively long filtration runs resulted from the removal of larger particles by these units, reducing significantly the turbidity of raw water. The slow sand filters presented larger than 90% of removal efficiency of color, turbidity, suspended solids and total iron, removal over 80% of consumed oxygen and above 95% for coliforms removal. Overall, the slow sand filters showed satisfactory performance in removing turbidity, iron and total coliforms. In particular, the slow sand filter with sand and granular activated carbon layers was more efficient in removing true color and consumed oxygen than the filter with single sand layer. Although peaks of color and turbidity during the fourth and last filtration runs, the FiME system proved to be efficient in removing total coliforms and E.coli in the last three weeks of operation. In the last filtration run, a comparison of the effluent water quality between the FiME system and a conventional full scale treatment plant was carried out for the removal of turbidity and color. Results showed that the FiME system produced similar water quality to the conventional treatment plant when turbidity was < 1,0. In general, results suggest that the FiME is an effective system to produce water quality from surface water with high levels of total coliforms and E.coli and peaks of color and turbidity according to the recommendations of the Portaria 518/2004 of the Ministry of Health, Brazil

Descrição

Citação

PEREZ, Wanderlei Elias. Evaluation of the Eficiency of a Multi-Stage Filtration System in Treating Water of the Sozinha Creek in Goianápolis, State of Goiás, Brazil.. 2009. 120 f. Dissertação (Mestrado em Engenharias) - Universidade Federal de Goiás, Goiânia, 2009.