Use este identificador para citar ou linkar para este item: http://repositorio.bc.ufg.br/handle/ri/13396
Tipo do documento: Artigo
Título: Emprego da abraçadeira de náilon na orquiectomia em equinos
Título(s) alternativo(s): Use of the nylon clamp in the equine orchiectomy
Autor: Silva, Luiz Antônio Franco da
França, Rodrigo Oliveira
Vieira, Dirson
Sousa, Vinícius Rodrigues de
Franco, Leandro Guimarães
Moura, Maria Ivete
Silva, Marco Augusto Machado
Trindade, Bruno Rodrigues
Costas, Gustavo Lage
Bernarde, Karollina Moraes
Resumo: Em alguns criatórios os métodos de orquiectomia em eqüinos ainda são realizados por leigos e de forma empírica, sem atenção à higiene e a hemostasia preventiva dos vasos que compõem o cordão espermático, resultando muitas vezes em óbito do animal. O objetivo desse estudo foi avaliar a eficácia da abraçadeira de náilon, na orquiectomia em eqüinos, como método hemostático, possíveis complicações pós-operatórias e o custo do procedimento. Foram empregados 24 animais machos não castrados, sem raça definida (SRD), clinicamente saudáveis, com peso corporal variando entre 300 kg e 400 kg e faixa etária entre três a oito anos. Avaliou-se os resultados dos procedimentos cirúrgicos por meio de exames clínicos, hematológicos e a ocorrência de complicações trans e pós-operatórias. Além da presença de edema nos eqüinos de todos os grupos, ocorreu um óbito quando se utilizou o emasculador. A abraçadeira de náilon subjetivamente avaliada mostrou-se resistente a tração exercida no local da aplicação e quando comparada ao uso do emasculador e categute apresentou menor custo e reduziu o tempo de duração do procedimento.
Abstract: In some horse breeding farms, the orchiectomy methods is still being practiced not scientifically by unprofessional people, without attention to hygiene and preventive hemostasy of the vessel from the spermatic cord, which usually results in death. The aim of this study was to evaluate the efficacy of the nylon clamp as an hemostatic method on the orchiectomy in equines, to describe possible post operative complications and the cost of the surgical procedure. 24 non castrated male equines, not defined breed, clinically health, between 300 and 400 kg of corporal weight and between three and eight years old were studied. The results of the surgical procedures were evaluated by clinical and hematologic exams and the occurrence of trans and post operative complications. There was edema in the animals of all groups and one death when the emasculator was employed. The nylon clamp was subjectively evaluated and have shown resistance to traction upon the place of the ligature when compared to the use the emasculator and catgut, lower cost and have decreased the time of surgical procedure.
Palavras-chave: Castração
Equino
Hemostasia
Poliamida náilon
Castration
Equine
Hemostasy
Nylon poliamide
País: Brasil
Unidade acadêmica: Escola de Veterinária e Zootecnia - EVZ (RG)
Citação: SILVA, Luiz Antônio Franco da; FRANÇA, Rodrigo Oliveira; VIEIRA, Dirson; SOUSA, Vinícius Rodrigues de; FRANCO, Leandro Guimarães; MOURA, Maria Ivete; SILVA, Marco Augusto Machado; TRINDADE, Bruno Rodrigues; COSTAS, Gustavo Lage; BERNARDE, Karollina Moraes. Emprego da abraçadeira de náilon na orquiectomia em eqüinos. Acta Scientiae Veterinariae, Porto Alegre, v. 34, n. 3, p. 261-266, 2006.
Tipo de acesso: Acesso Aberto
URI: http://repositorio.bc.ufg.br/handle/ri/13396
Data de publicação: 2006
Aparece nas coleções:EVZ - Artigos publicados em periódicos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Artigo - Luiz Antônio Franco da Silva - 2006.pdf176,72 kBAdobe PDFThumbnail
Baixar/Abrir


Este item está licenciada sob uma Licença Creative Commons Creative Commons