Título: Use of magnetic resonance to investigate magnetic fluids for transformers application
Autor: Leite, Eliane Silva
Skeff Neto, K.
Sartoratto, Patrícia Pommé Confessori
Viali, Wesley Renato
Morais, P. C.
Resumo: Resonancia magn´etica (RM) fue utilizada para investigar dos muestras de fluidos magn´eticos (FM) conteniendo nanopart´ıculas (di´ametro medio de 3 nm) de ´oxido de hierro suspendidas en un aislante mineral y aceite vegetal. El espectro de RM fue analizado usando dos componentes de forma lorentziana. El an´alisis de la dependencia de la temperatura (T) con el campo resonante (HR) indica que a bajos campos (campos superiores) la linea de resonancia produce mon´omeros (unidades tipo cadena). En la transici´on de fase solida-liquido las muestras de FM pr´oximo al punto de descongelamiento del aceite aislante (solvente), es indicado por la c´uspide en la curva HR £ T, que es m´as pronunciada para la componente de la linea de resonancia a bajos campos. Este ajuste fue asociado para la alta reorientaci ´on de los momentos magn´eticos de los mon´omeros encima del punto de descongelamiento de las muestras de FM.
Abstract: Magnetic resonance (MR) was used to investigate two magnetic fluid (MF) samples containing nanosized (average 3 nm in diameter) iron oxide particles suspended in insulating mineral and vegetal oils. The MR spectra were analyzed using two Lorentzian-like components. Analysis of the temperature (T) dependence of the resonance field (HR) indicates that the lower-field (higher-field) resonance line accounts for monomers (chain-like units). The solid-liquid phase transition of the MF samples, taking place around the melting point of the insulating oil (solvent), is indicated by a cusp in the HR £ T curve, which is more pronounced for the lower-field resonance line component. This finding was associated to a higher reorientation of the monomer’s magnetic moment upon melting of the MF sample.
Palavras-chave: Transformer
Magnetic fluid
Magnetic resonance
Nanoparticle
Trasformador
Fluido magnético
Resonancia magnética
Nanopartículas
País: Mexico
Unidade acadêmica: Instituto de Química - IQ (RG)
Citação: LEITE, E.S. et al. Use of magnetic resonance to investigate magnetic fluids for transformers application. Revista Mexicana de Física, Coyoacán, v. 58, n. 2, p. 249-252, Dec. 2012.
Tipo de acesso: Acesso Aberto
URI: http://repositorio.bc.ufg.br/handle/ri/16228
Data de publicação: Dez-2012
Aparece nas coleções:IQ - Artigos publicados em periódicos

Arquivos associados a este item:
Arquivo Descrição TamanhoFormato 
Artigo - Eliane Silva Leite - 2012.pdf340,65 kBAdobe PDFThumbnail
Baixar/Abrir


Este item está licenciada sob uma Licença Creative Commons Creative Commons