Dosimetry of the cone beam computed tomography Veraviewepocs 3D compared with the 3D Accuitomo in different fields of view

dc.creatorHirsch, E.
dc.creatorWolf, U.
dc.creatorSilva, Maria Alves Garcia Santos
dc.date.accessioned2020-03-04T14:23:30Z
dc.date.available2020-03-04T14:23:30Z
dc.date.issued2008
dc.description.abstractObjectives: This study compares tissue-absorbed and effective doses of the cone beam CT (CBCT) units, the Veraviewepocs 3D and the 3D Accuitomo, in different protocols. Methods: The absorbed organ doses were measured using an anthropomorphic phantom loaded with thermoluminescent dosemeters (TLDs) in 16 sensitive organ sites. Both CBCT units were deployed with different fields of view (FOVs): 3D Accuitomo using two protocols (anterior 464 cm scan and anterior 666 cm scan) and Veraviewepocs 3D using three protocols (anterior 464 cm scan, anterior 864 cm scan and panoramic + anterior 464 cm). Equivalent and effective doses were then calculated, the latter based on the International Commission on Radiological Protection’s (ICRP) 2005 recommendations. Results: The lowest effective dose was observed for the 3D Accuitomo 464 cm (20.02 mSv), the highest for the 3D Accuitomo 666 cm (43.27 mSv). The effective dose recorded for Veraviewepocs 3D was 39.92 mSv for the 864 cm scan, 30.92 mSv for the 464 cm scan and 29.78 mSv for the panoramic + 464 cm scan protocol. Conclusions: The radiation doses delivered by both machines were in comparable ranges when using 464 cm FOV. A smaller FOV should be used for dental images, whereas a larger FOV should be restricted to cases in which a wider view is required.pt_BR
dc.identifier.citationHIRSCH, E.; WOLF, U.; HEINICKE, F.; SILVA, M. A. G. Dosimetry of the cone beam computed tomogaphy Veraviewepocs 3D compared with the 3D accuitomo in different fields of view. Dento-Maxillo-Facial Radiology, Oxford, v. 37, p. 268-273, 2008.pt_BR
dc.identifier.doi10.1259/dmfr/23424132
dc.identifier.issn0250-832X
dc.identifier.urihttp://repositorio.bc.ufg.br/handle/ri/18805
dc.language.isoengpt_BR
dc.publisher.countryGra-bretanhapt_BR
dc.publisher.departmentFaculdade de Odontologia - FO (RG)pt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectThermoluminescent dosimetypt_BR
dc.subjectCone beam computed tomographypt_BR
dc.subjectTomographypt_BR
dc.subjectX-ray computedpt_BR
dc.subjectRadiographypt_BR
dc.subjectPanoramicpt_BR
dc.titleDosimetry of the cone beam computed tomography Veraviewepocs 3D compared with the 3D Accuitomo in different fields of viewpt_BR
dc.typeArtigopt_BR

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Artigo - E. Hirsch - 2008.pdf
Tamanho:
109.6 KB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: