Demanda total de água do feijoeiro nos sistemas de plantio convencional e direto

dc.creatorNascimento, Jorge Luiz do
dc.creatorStone, Luis Fernando
dc.creatorOliveira, Luiz Fernando Coutinho de
dc.date.accessioned2017-11-24T10:23:10Z
dc.date.available2017-11-24T10:23:10Z
dc.date.issued2001-12
dc.description.abstractA line source with a five-band irrigation experiment was used to determined the total common bean water demand under conventional and no-tillage systems. Irrigation was controlled by two tensiometer sets installed in the second band parallel to the line source. The no-tillage system resulted in a 20% reduction in irrigation water demand as compared to the conventional system. The total estimated demand based on the class “A” evaporation tank overestimated the tensiometer determined demand for conventional and no-tillage systems by 11% and 29%, respectively.pt_BR
dc.description.resumoEm um experimento com cinco faixas de irrigação, obtidas por uma linha central de aspersão, determinou-se a demanda total de água do feijoeiro nos sistemas de plantio convencional e direto. O controle da irrigação foi feito por duas baterias de tensiômetros instaladas na segunda faixa paralela à linha de aspersão. O sistema de plantio direto proporcionou economia de 20% de água de irrigação em relação ao plantio convencional. A demanda total estimada com base na evaporação do tanque classe “A”, superestimou em 11,0% e 29,0% a demanda determinada por tensiometria para os sistemas de plantio convencional e direto, respectivamente.pt_BR
dc.description.sponsorshipUFGpt_BR
dc.identifier.citationNASCIMENTO, Jorge Luiz do; STONE, Luis Fernando; OLIVEIRA, Luiz Fernando Coutinho de. Demanda total de água do feijoeiro nos sistemas de plantio convencional e direto. Pesquisa Agropecuária Tropical, Goiânia, v. 31, n. 2, p. 159-161, jul./dez. 2001. Disponível em: <https://www.revistas.ufg.br/pat/article/view/2485>.pt_BR
dc.identifier.issn1517-6398
dc.identifier.urihttp://repositorio.bc.ufg.br/handle/ri/12990
dc.language.isoporpt_BR
dc.publisherJoão Batista Duartept_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentEscola de Agronomia e Engenharia de Alimentos - EAEA (RG)pt_BR
dc.publisher.initialsUFGpt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectPlantio diretopt_BR
dc.subjectTensiômetropt_BR
dc.subjectIrrigaçãopt_BR
dc.subjectNo-tillagept_BR
dc.subjectTensiometerpt_BR
dc.subjectIrrigationpt_BR
dc.titleDemanda total de água do feijoeiro nos sistemas de plantio convencional e diretopt_BR
dc.title.alternativeTotal common bean water demand under conventional and no-tillage systemspt_BR
dc.typeArtigopt_BR

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Artigo - Jorge Luiz do Nascimento - 2001.pdf
Tamanho:
22.01 KB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: