Validity and reliability of a 10 and 20 m linear sprint protocol using a single-beam photocell system: an exploratory study with young male soccer players

dc.creatorMorais, João Pedro Araújo
dc.creatorSantiago, Paulo Roberto Pereira
dc.creatorLira, Claudio Andre Barbosa de
dc.creatorVieira, Carlos Alexandre
dc.creatorLima, Ramon Ribeiro de
dc.creatorCosta, Gustavo de Conti Teixeira
dc.creatorCampos, Mário Hebling
dc.date.accessioned2026-05-14T10:56:56Z
dc.date.available2026-05-14T10:56:56Z
dc.date.issued2026
dc.description.abstractSingle-beam photocell systems are the most cost-effective type of timing gates and are widely used to assess linear sprint performance. However, for short distances (<30 m), their validity may be compromised by early movement artifacts (e.g., arm swing, trunk lean, and foot motion), especially when the first timing gate is positioned very close to the athlete and at heights easily crossed by body segments. There is a need to develop low-cost standardized devices and protocols for timing short linear sprints. This exploratory study examined the validity and reliability of a single-beam photocell system applied to a short-distance linear sprint protocol with the initial timing gate positioned approximately below knee height (0.40 m) and a 0.5 m starting distance. Sixteen pre-professional young male soccer players [19.4 ± 1.4 years; 74.8 ± 6.8 kg; 1.79 ± 0.07 m] completed two 20 m linear sprints. Split (10 m) and total times were recorded simultaneously using a custom-built single-beam photocell system and a 240 fps (frames per second) panning camcorder (reference method). Results suggested good to excellent test-retest reliability [ICC ≥ 0.79; CV ≤ 1.26%], and good validity [ICC ≥ 0.84; CV ≤ 1.21%; Mean absolute error ≤ 0.040 s (1.40%)]. Systematic biases with small effect sizes between methods (p < 0.01; d < 0.5) indicated that photocell and video-based measurements are not fully interchangeable. This exploratory study suggests that the proposed photocell protocol is reliable for short-distance linear sprint assessment. The source code and hardware schematics are openly available, facilitating replication and adaptation.
dc.identifier.citationMORAES, João Pedro Araújo et al. Validity and reliability of a 10 and 20 meter linear sprint protocol USING a single-beam photocell system: an exploratory study with young male soccer players. Football Studies, Amsterdam, v. 1, e100045, 2026. DOI: 10.1016/j.footst.2026.100045. Disponível em: https://www.sciencedirect.com/science/article/pii/S3051268926000255. Acesso em: 11 maio 2026.
dc.identifier.doi10.1016/j.footst.2026
dc.identifier.issn3051-2689
dc.identifier.urihttps://repositorio.bc.ufg.br//handle/ri/30366
dc.language.isoeng
dc.publisher.countryHolanda
dc.publisher.departmentFaculdade de Educação Física e Dança - FEFD (RMG)
dc.rightsAcesso Aberto
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectRunning
dc.subjectKinematics
dc.subjectBiomechanics
dc.subjectSoccer
dc.subjectConcurrent validation
dc.titleValidity and reliability of a 10 and 20 m linear sprint protocol using a single-beam photocell system: an exploratory study with young male soccer players
dc.typeArtigo

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Artigo - João Pedro Araújo Morais - 2026.pdf
Tamanho:
2.28 MB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: