Molecular diagnostics of dengue by reverse transcription-loop mediated isothermal amplification (RT-LAMP) in disposable polyester-toner microdevices

dc.creatorMendes, Geovana de Melo
dc.creatorOliveira, Kézia Gomes de
dc.creatorBorba, Juliane Cristina
dc.creatorOliveira, Thais Santana de
dc.creatorFiaccadori, Fabíola Souza
dc.creatorNogueira, Maurício Lacerda
dc.creatorBailão, Alexandre Melo
dc.creatorCarrilho, Emanuel
dc.creatorDuarte, Gabriela Rodrigues Mendes
dc.date.accessioned2024-01-25T14:16:51Z
dc.date.available2024-01-25T14:16:51Z
dc.date.issued2019-05-14
dc.description.abstractDengue is one of the most prevalent infectious tropical diseases in the world, with high incidence in over 100 countries. Rapid and reliable diagnosis of dengue is of great importance for public health. To simplify molecular diagnostics, isothermal amplification techniques have recently emerged as an alternative to conventional methods of deoxyribonucleic acid (DNA) amplification. Here, we developed a one-step method for dengue virus detection from real sample based on RT-LAMP (reverse transcription-loop mediated isothermal amplification) in a disposable microdevice. The reaction was thermally controlled with a thermoblock for 15 min at 72 °C. At the end of the incubation time, we either removed the solution for detection of fragments by gel electrophoresis or added DNA intercalator for visual detection on-chip. Our results demonstrated that it is possible to detect dengue virus through RT-LAMP directly from a serum sample, without previous ribonucleic acid (RNA) extraction. The success of RT-LAMP was confirmed in reactions initiated with 0.8 fg μL−1 of RNA, which represents 200 copies of RNA per µL. RT-LAMP in a polyester-toner (PeT) microdevice is a simple and inexpensive method that allows for rapid detection of dengue virus with high reliability and great potential for point-of-care applications.
dc.identifier.citationMENDES, Geovana M. et al. Molecular diagnostics of dengue by reverse transcription-loop mediated isothermal amplification (RT-LAMP) in disposable polyester-toner microdevices. Journal of the Brazilian Chemical Society, Campinas, v. 30, n. 9, p. 1841-1849, 2019. DOI: 10.21577/0103-5053.20190092. Disponível em: https://jbcs.sbq.org.br/default.asp?ed=289. Acesso em: 13 dez. 2023.
dc.identifier.doi10.21577/0103-5053.20190092
dc.identifier.issne- 1678-4790
dc.identifier.issn0103-5053
dc.identifier.urihttp://repositorio.bc.ufg.br//handle/ri/24183
dc.language.isoeng
dc.publisher.countryBrasil
dc.publisher.departmentInstituto de Química - IQ (RMG)
dc.rightsAcesso Aberto
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectRT-LAMP
dc.subjectPeT microdevice
dc.subjectDengue virus
dc.subjectMolecular diagnosis
dc.subjectPoint-of-care
dc.titleMolecular diagnostics of dengue by reverse transcription-loop mediated isothermal amplification (RT-LAMP) in disposable polyester-toner microdevices
dc.typeArtigo

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Artigo - Geovana de Melo Mendes - 2019.pdf
Tamanho:
1.32 MB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: