Changes in occlusal vertical dimension in microwave processing of complete dentures
| dc.creator | Barbosa, Débora Barros | |
| dc.creator | Compagnoni, Marco Antonio | |
| dc.creator | Leles, Cláudio Rodrigues | |
| dc.date.accessioned | 2019-01-24T11:39:56Z | |
| dc.date.available | 2019-01-24T11:39:56Z | |
| dc.date.issued | 2002 | |
| dc.description.abstract | This study investigated the effect of different microwave curing cycles on the changes in occlusal vertical dimension of complete dentures. Four test groups with 12 maxillary dentures each were evaluated. Groups 1, 2 and 3 were polymerized with different cycles by microwave radiation and Group 4 was the control and cured by water bath. The average pin opening for all groups was less than 0.5 mm. There was no significant difference between the groups polymerized by the microwave method and the control group. However, analyses of the vertical dimension changes showed statistically significant differences between groups 2 (0.276 ± 0.141 mm) and 3 (0.496 ± 0.220 mm). | pt_BR |
| dc.description.resumo | Este estudo avaliou o efeito de diferentes ciclos de polimerização sobre a dimensão vertical de oclusão em próteses totais. Quatro grupos experimentais, cada um contendo 12 próteses totais superiores foram avaliados. Os grupos 1, 2 e 3 foram polimerizados através da energia de microondas em diferentes ciclos e para o Grupo 4 a polimerização foi realizada em banho de água quente e este grupo foi utilizado como controle nesta pesquisa. Os resultados evidenciaram uma média de afastamento do pino incisal da mesa incisal do articulador inferior a 0,5 mm para todos os grupos avaliados. Não existiu diferença significante entre os grupos polimerizados por microondas e o grupo controle. No entanto, existiu diferença significante entre as alterações verticais dos grupos 2 (0,276 ± 0,141 mm) e 3 (0,496 ± 0,220 mm). | pt_BR |
| dc.identifier.citation | BARBOSA, Débora Barros; COMPAGNONI, Marco Antonio; LELES,Cláudio Rodrigues. Changes in occlusal vertical dimension in microwave processing of complete dentures. Brazilian Dental Journal, Ribeirão Preto, v. 13, n. 3, p. 197-200, 2002. | pt_BR |
| dc.identifier.doi | 10.1590/S0103-64402002000300011 | |
| dc.identifier.issn | 0103-6440 | |
| dc.identifier.issn | e- 1806-4760 | |
| dc.identifier.uri | http://repositorio.bc.ufg.br/handle/ri/16835 | |
| dc.language.iso | eng | pt_BR |
| dc.publisher.country | Brasil | pt_BR |
| dc.publisher.department | Faculdade de Odontologia - FO (RG) | pt_BR |
| dc.rights | Acesso Aberto | pt_BR |
| dc.subject | Complete denture | pt_BR |
| dc.subject | Microwave | pt_BR |
| dc.subject | Vertical dimension | pt_BR |
| dc.subject | Acrylic resin | pt_BR |
| dc.subject | Prótese total | pt_BR |
| dc.subject | Microondas | pt_BR |
| dc.subject | Dimensão vertical | pt_BR |
| dc.subject | Resina acrílica | pt_BR |
| dc.title | Changes in occlusal vertical dimension in microwave processing of complete dentures | pt_BR |
| dc.title.alternative | Alteração da dimensão vertical de oclusão de próteses totais polimerizadas através da energia de microondas | pt_BR |
| dc.type | Artigo | pt_BR |