Influence of the powder/liquid ratio and storage time of conventional glass ionomer cements in diametral tensile strength
| dc.creator | Silva, Tamiris Carolina da | |
| dc.creator | Santos, Camila Rodrigues dos | |
| dc.creator | Fonseca, Rodrigo Borges | |
| dc.creator | Barata, Terezinha de Jesus Esteves | |
| dc.date.accessioned | 2020-09-18T15:52:48Z | |
| dc.date.available | 2020-09-18T15:52:48Z | |
| dc.date.issued | 2014-12 | |
| dc.description.abstract | Introduction: The Glass Ionomer Cements (GICs) are the most versatile dental material with extensive clinical indication. However, the mechanical strength of conventional GICs (C-GICs) is still unsatisfactory under areas of masticatory forces. Objective: To evaluate the influence of C-GIC proportioning system (powder-liquid and encapsulated) and storage period (1h, 24h and 7 days) on Diametral Tensile Strength (DTS). Material and methods: The two variables were tested in relation to C-GIC (Riva Self Cure, SDI, Australia). The following proportioning systems were tested: powder-liquid by weight (g:g) and powder-liquid by volume (flat scoop: drop) and encapsulated system (pre-dosed capsules). Five C-GIC specimens were prepared, according to ISO specification #9917 for each variable to be studied. The specimens were stored in plastic containers containing distilled water and kept at 37ºC and 100% humidity until the mechanical testing in a universal testing machine (Instron Corp., USA) at a speed 0.5 mm/min. The data were submitted to two-way ANOVA and Tukey test for multiple comparisons (α = 0.05). Results: The proportioning system (P < 0.0001) and storage time (P < 0.0001) were significant predictors of DTS, however with no interaction between these factors. Conclusion: The DTS of C-GICs was influenced by storage time (1 hour < 24 hours < 7 days) and by the proportioning system only for the initial period of its setting reaction. | pt_BR |
| dc.identifier.citation | SILVA, Tamiris Carolina da et al. Influence of the powder/liquid ratio and storage time of conventional glass ionomer cements in diametral tensile strength. RSBO, Joinville, v. 11, n. 4, p. 387-392, 2014. | pt_BR |
| dc.identifier.issn | 1984-5685 | |
| dc.identifier.uri | http://repositorio.bc.ufg.br/handle/ri/19040 | |
| dc.language.iso | eng | pt_BR |
| dc.publisher.country | Brasil | pt_BR |
| dc.publisher.department | Faculdade de Odontologia - FO (RG) | pt_BR |
| dc.rights | Acesso Aberto | pt_BR |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/us/ | * |
| dc.subject | Dental research | pt_BR |
| dc.subject | Material resistance | pt_BR |
| dc.subject | Glass ionomer cements | pt_BR |
| dc.title | Influence of the powder/liquid ratio and storage time of conventional glass ionomer cements in diametral tensile strength | pt_BR |
| dc.type | Artigo | pt_BR |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- Artigo - Tamiris Carolina da Silva - 2014.pdf
- Tamanho:
- 220.54 KB
- Formato:
- Adobe Portable Document Format
- Descrição:
Licença do Pacote
1 - 1 de 1
Carregando...
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: