Internal fixation of short bilateral sagittal split osteotomy of the mandibular ramus: a mechanical evaluation

dc.creatorAraújo Filho, Nilton Pires de
dc.creatorVale, Daniel Santiago
dc.creatorSouza, Alann Thaffarell Portilho de
dc.creatorBorba, Alexandre Meireles
dc.creatorFreitas, Gileade Pereira
dc.creatorLopes, Helena Bacha
dc.date.accessioned2025-12-30T17:54:15Z
dc.date.available2025-12-30T17:54:15Z
dc.date.issued2025-04
dc.description.abstractThis study evaluated in vitro three internal fixation methods for short bilateral sagittal split osteotomy (BSSO) of the mandibular ramus using polyurethane replicas. After simulating an 8-mm mandible advancement with a counterclockwise rotation of 6° to the occlusal plane, the short BSSO was fixed bilaterally by using: (i) three linear bicortical screws; (ii) one miniplate with four monocortical screws and one bicortical screw (hybrid system); and (iii) two miniplates with eight monocortical screws. The load was measured on the central incisors or first molars bilaterally at the displacements of 1, 3, 5, and 7 mm. The data were analyzed using one-way analysis of variance (ANOVA) with Tukey's post hoc test. In addition, a linear regression analysis with dummy variables was performed for each combination of displacement and loading point. There were no statistically significant differences in the loads applied to both central incisors and first molars bilaterally among fixation methods at 1-mm displacement. However, the necessary load was larger for the two miniplates method for 3-, 5-, and 7-mm displacements. Considering the biomechanical aspects and the cost benefit related to the fixation materials, using three linear bicortical screws or a hybrid system may be more favorable than employing two miniplates with eight monocortical screws.
dc.identifier.citationARAÚJO FILHO, Nilton Pires de et al. Internal fixation of short bilateral sagittal split osteotomy of the mandibular ramus: a mechanical evaluation. European Journal of Oral Sciences, [s. l.], v. 133, n. 2, e70006, 2025. DOI: 10.1111/eos.70006. Disponível em: https://onlinelibrary.wiley.com/doi/10.1111/eos.70006. Acesso em: 12 dez. 2025.
dc.identifier.doi10.1111/eos.70006
dc.identifier.issn0909-8836
dc.identifier.issne- 1600-0722
dc.identifier.urihttps://onlinelibrary.wiley.com/doi/10.1111/eos.70006
dc.language.isoeng
dc.publisher.countryGra-bretanha
dc.publisher.departmentFaculdade de Odontologia - FO (RMG)
dc.rightsAcesso Restrito
dc.subjectBone screw
dc.subjectInternal fixation device
dc.subjectOrthognathic surgery
dc.subjectOsteotomy
dc.titleInternal fixation of short bilateral sagittal split osteotomy of the mandibular ramus: a mechanical evaluation