Use of condensed water from air conditioning systems

dc.creatorScalize, Paulo Sergio
dc.creatorSoares, Samara Silva
dc.creatorAlves, Andreia Cristina Fonseca
dc.creatorMarques, Thaynara Azevedo
dc.creatorMesquita, Gabriel Gade Martins
dc.creatorBallaminut, Nara
dc.creatorAlbuquerque, Antonio Carvalho João
dc.date.accessioned2025-05-05T18:34:53Z
dc.date.available2025-05-05T18:34:53Z
dc.date.issued2018
dc.description.abstractFacing the growing demand for water, discussions on environmental sustainability and conservation of this resource have become increasingly important. Among the possibilities for water conservation, air conditioning systems have potential applicability because, during their operation, water is generated via the condensation of air humidity, which is normally discarded. Thus, the objective of this work was to evaluate the water released by air conditioning equipment (condensed water) installed in the Laboratory of Water Analysis (LAnA) qualitatively and quantitatively, in order to verify its potential for use in the laboratory itself. For this, the quality of the water produced by three air conditioners was compared water quality parameters found in the literature, as well as with water produced by a distiller and an ultra-purifier, both used in the LAnA. Water quality was evaluated using physicochemical parameters (i.e. pH, electrical conductivity, resistivity, alkalinity, turbidity, apparent color and hardness) and microbiological parameters (i.e. total coliforms, Escherichia coli and heterotrophic bacteria). The average water flow produced by the three monitored air conditioners was 3.08 L/hour, which is higher than the daily consumption by the LAnA, indicating that its use would be quantitatively propitious. The physicochemical and microbiological analyses found that, condensed water can be used in the routine activities of LAnA. However, for its use as reagent-grade water, a prior treatment would be necessary, mainly due to the presence of heterotrophic bacteria
dc.identifier.citationSCALIZE, Paulo Sergio et al. Use of condensed water from air conditioning systems. Open Engineering, [s. l.], v. 8, n. 1, p. 284–292, 2018. DOI: 10.1515/eng-2018-0031. Disponível em: https://www.degruyter.com/document/doi/10.1515/eng-2018-0031/html?srsltid=AfmBOop9625nT781Rr3JIn6sm0ABT0ypDpYCYyeNhWVvnY-J6UjVOjiG. Acesso em: 30 jsn. 2025.
dc.identifier.doi10.1515/eng-2018-0031
dc.identifier.issne- 2391-5439
dc.identifier.urihttp://repositorio.bc.ufg.br//handle/ri/27430
dc.language.isoeng
dc.publisher.countryOutros
dc.publisher.departmentEscola de Engenharia Civil e Ambiental - EECA (RMG)
dc.rightsAcesso Aberto
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectReagent-grade water
dc.subjectAir conditioning
dc.subjectWater use
dc.subjectLaboratory
dc.titleUse of condensed water from air conditioning systems
dc.typeArtigo

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Artigo - Paulo Sergio Scalize - 2018.pdf
Tamanho:
1.02 MB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: