dc.description.abstractIn recent years, there has been an increase in search of equipment that promise to reduce the water consumption through there move of air into the pipes, preventing it from be in measured as water. Thus, this work aims to verify the efficiency of a air blocking equipment to the supply situation of the city under study. By laboratory tests with different flow rates and pressures and field checks in two buildings, we found that in most cases, air blockers do not interfere in the performance of the water meter and that any reduction in consumption may be due to the loss of load on the system, generated by the equipment and not for control of the air into the pipes.pt_BR
dc.description.resumoNos últimos anos, observa-se um aumento da busca de equipamentos que prometem reduzir o consumo de água através da retirada de ar das tubulações, impedindo que este seja contabilizado como água. Sendo assim, este trabalho visa verificar a eficiência de um equipamento bloqueador de ar para a situação de abastecimento da cidade em estudo. Através de testes laboratoriais com vazões e pressões diferenciadas e verificações em campo em duas edificações, foi possível verificar que na maioria dos casos, os bloqueadores de ar não interferem no desempenho do hidrômetro e que uma eventual redução no consumo pode ser em decorrência da perda de carga no sistema, gerada pelo equipamento e não pelo controle do ar.pt_BR
dc.identifier.citationSCALIZE, Paulo Sergio; LEITE, Wellington Cyro de Almeida; CAMPOS, Marcus André Siqueira. Influência da válvula bloqueadora de ar instalada após o hidrômetro. Universitas, Araçatuba, v. 7, p. 135-147, 2015.pt_BR
dc.identifier.issn1984-7459
dc.identifier.urihttp://repositorio.bc.ufg.br/handle/ri/14573
dc.language.isoporpt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentEscola de Engenharia Civil e Ambiental - EECA (RG)pt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectHidrômetropt_BR
dc.subjectBloqueador de arpt_BR
dc.subjectControlador de arpt_BR
dc.subjectEliminador de arpt_BR
dc.subjectRede de abastecimentopt_BR
dc.subjectWater meters airpt_BR
dc.subjectBlocking devicespt_BR
dc.subjectAir controlpt_BR
dc.subjectAir eliminatorspt_BR
dc.subjectWater supply networkpt_BR
dc.titleInfluência da válvula bloqueadora de ar instalada após o hidrômetropt_BR
dc.title.alternativeInfluence of the air block value installed after water meterspt_BR
dc.typeArtigopt_BR

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Artigo - Paulo Sergio Scalize - 2015.pdf
Tamanho:
1.36 MB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: