Mixed-mode adhesive tape integrated in a syringe plunger: an affordable microextraction device for isolating basic drugs from saliva samples
Carregando...
Data
Título da Revista
ISSN da Revista
Título de Volume
Editor
Resumo
Background: Current bioanalytical laboratories must cope with increasing pressure on workflow due to the high
number of samples to process and the speed required to generate analytical information. The development of
cost-effective extraction procedures capable of processing multiple samples simultaneously can address, or at
least mitigate, this enormous challenge. These devices must be affordable and cost-effective, taking into account
that disposable units are preferred when biosamples are processed to avoid contamination of operators and
carryover effects.
Results: In this work, sorptive plunger-based in-syringe microextraction (SP-ISME) is presented and evaluated for
the isolation of seven basic drugs from saliva samples. The extraction device consists of a conventional plastic
syringe whose plunger has been coated with mixed-mode cationic exchange (MCX) microparticles using a double-sided adhesive tape as binder. In this case, the sample is aspirated into the syringe, where it is incubated
for a defined time under continuous agitation, minimizing handling and allowing multiple samples to be
extracted simultaneously. The main variables involved in the SP-ISME (i.e., sample dilution, ionic strength,
stirring rate, extraction time, and elution time) have been evaluated in detail. After extraction, the analytes were
analyzed by high-performance liquid chromatography coupled with tandem mass spectrometry. The analytical
performance showed competitive results, yielding limits of quantification of 0.5 μg L− 1 for all analytes, with
intra- and inter-day precision lower than 6.1% and 13.2%, respectively, and relative recoveries between 81% and
110%.
Significance and novelty: The microextraction device is highly versatile, as it can be modified with various types of
microparticles, whether commercial or synthesized in the laboratory. Also, its design avoids backpressure, a
common issue in some in-syringe devices, because the sample is not flowed through the sorptive phase. The
stability of the analytes retained in the sorptive phase after extraction opens the door to on-site applications of
this technique.
Descrição
Citação
ARRATES, Yuri et al. Mixed-mode adhesive tape integrated in a syringe plunger: an affordable microextraction device for isolating basic drugs from saliva samples. Analytica Chimica Acta, Amsterdam, v. 1423, e346173, 2026. DOI: 10.1016/j.aca.2026.346173. Disponível em: https://www.sciencedirect.com/science/article/pii/S0003267026011232. Acesso em: 14 set. 2026.