Evaluation of water level in flowing channels using ultrasonic sensors

dc.creatorPereira, Tatiane Souza Rodrigues
dc.creatorCarvalho, Thiago Pires de
dc.creatorMendes, Thiago Augusto
dc.creatorFormiga, Klebber Teodomiro Martins
dc.date.accessioned2025-03-13T21:45:14Z
dc.date.available2025-03-13T21:45:14Z
dc.date.issued2022-05
dc.description.abstractMonitoring flow in channels is difficult, expensive, and potentially dangerous; hence, alternatives minimizing these factors are sought and indirect methods to measure the flow based on water-level information, among others, are employed. Ultrasonic sensors along with Arduino are widely used to monitor levels in reservoirs; however, the accuracy of this method in turbulent flow regimes has not been evaluated. Therefore, in this study, we evaluated the level of open channel flows using a combination of Arduino and ultrasonic sensors whilst considering turbulence. Additionally, we statistically compared the simultaneous measurements of levels obtained using five ultrasonic sensors with those of five rulers filmed individually along an artificial channel, for four permanent and two transient regimes. The results showed that the errors in measurements increased with increasing turbulence. These errors were within the range of hydraulic measurements (<0.020 m), indicating that the procedure is valid for experienced conditions. Therefore, the combination of Arduino and ultrasonic sensors is a technically and economically viable alternative. However, calibrating and validating the sensors for distances greater than 0.400 m should be performed with care because the bench tests performed in static conditions were limitedly accurate in measuring distances greater than 0.200 m.
dc.identifier.citationPEREIRA, Tatiane Souza Rodrigues; CARVALHO, Thiago Pires de; MENDES, Thiago Augusto; FORMIGA, Klebber Teodomiro Martins. Evaluation of water level in flowing channels using ultrasonic sensors. Sustainability, Basileia, v. 14, n. 9, e5512, 2022. DOI: 10.3390/su14095512. Disponível em: https://www.mdpi.com/2071-1050/14/9/5512. Acesso em: 13 Mar. 2025.
dc.identifier.doi10.3390/su14095512
dc.identifier.issne- 2071-1050
dc.identifier.urihttp://repositorio.bc.ufg.br//handle/ri/26979
dc.language.isoeng
dc.publisher.countrySuica
dc.publisher.departmentEscola de Engenharia Civil e Ambiental - EECA (RMG)
dc.rightsAcesso Aberto
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectSteady flow
dc.subjectTransient flow
dc.subjectArduino
dc.subjectHC-SR04 sensor
dc.titleEvaluation of water level in flowing channels using ultrasonic sensors
dc.typeArtigo

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Artigo - Klebber Teodomiro Martins Formiga - 2022.pdf
Tamanho:
4.08 MB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: