Role of surfactant molecules in magnetic fluid: comparison of monte carlo simulation and electron magnetic resonance

dc.creatorCastro, Leonardo Luiz e
dc.creatorGonçalves, Gil Renato Ribeiro
dc.creatorSkeff Neto, Kalil
dc.creatorMorais, Paulo César de
dc.creatorBakuziz, Andris Figueiroa
dc.creatorMiotto, Ronei
dc.date.accessioned2018-06-14T11:28:45Z
dc.date.available2018-06-14T11:28:45Z
dc.date.issued2008
dc.description.abstractWe investigate a magnetic fluid composed of magnetite nanoparticles surfacted with dodecanoic acid molecules and stably dispersed in a hydrocarbon solvent. A comparison between Monte Carlo simulation and different experimental techniques allows us to validate our methodology and investigate the behavior of the surfactant molecules. Our analysis, based on the Langmuir model, suggests that the surfactant grafting number on isolate nanoparticles increases with the nanoparticle concentration, while the grafting on agglomerated nanoparticles presents a more complicated behavior. Our results suggests that, if properly coated and at a certain concentration range, colloids can become stable even in the presence of agglomerates. The role of the Hamaker constant, which controls the van derWaals interaction intensity, was also investigated.We have found that the ratio between grafting and Hamaker constant governs the level of nanoparticle agglomeration.pt_BR
dc.identifier.citationCASTRO, L. L.; GONÇALVES, G. R. R.; SKEFF NETO, K.; MORAIS, P. C.; BAKUZIS, A. F.; MIOTTO, R. Role of surfactant molecules in magnetic fluid: comparison of monte carlo simulation and electron magnetic resonance. Physical Review. E, Melville, v. 78, n. 6, e061507, 2008.pt_BR
dc.identifier.doi10.1103/PhysRevE.78.061507
dc.identifier.issne- 1550-2376
dc.identifier.urihttp://repositorio.bc.ufg.br/handle/ri/15251
dc.language.isoengpt_BR
dc.publisher.countryEstados unidospt_BR
dc.publisher.departmentInstituto de Física - IF (RG)pt_BR
dc.rightsAcesso Abertopt_BR
dc.titleRole of surfactant molecules in magnetic fluid: comparison of monte carlo simulation and electron magnetic resonancept_BR
dc.typeArtigopt_BR

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Artigo - Leonardo Luiz e Castro - 2008.pdf
Tamanho:
492.37 KB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: