dc.description.abstract | Here we report for the first time the use of an electronic micropipette as hydrodynamic (HD) injector for microchip electrophoresis (ME) devices. The micropipette was directly coupled to a PDMS device, which had been fabricated in a simple cross format with two auxiliary channels for sample volume splitting. Sample flow during the injection procedure was controlled in automatic dispenser mode using a volume of 0.6 µL. Channel width and device configuration were optimized and the best results were achieved using a simple cross layout containing two auxiliary channels with 300 µm width for sample splitting. The performance of the HD injector was evaluated using a model mixture of high-mobility cationic species. The results obtained were compared to the data obtained via electrokinetic (EK) injection. Overall, the HD provided better analytical performance in terms of resolution and injection-to-injection repeatability. The relative standard deviation (RSD) values for peak intensities were lower than 5% (n=10) when the micropipette was employed. In comparison with EK injection, the use of the proposed HD injector revealed an unbiased profile for a mixture containing K+ and Li+(300 µmol L−1 each) over various buffer concentrations. For EK injection, the peak areas decreased from 2.92 ± 0.20–0.72 ± 0.14 V s for K+ and from 1.30 ± 0.10–0.38 ± 0.10 V s for Li+ when the running buffer increased from 20 to 50 mmol L−1. For HD injection, the peak areas for K+ and Li+ exhibited average values of 2.48±0.07 and 2.10±0.06 V s, respectively. The limits of detection (LDs) for K+, Na+ and Li+ ranged from 18 to 23 µmol L−1. HD injection through an electronic micropipette allows to automatically dispense a bias-free amount of sample inside microchannels with acceptable repeatability. The proposed approach also exhibited instrumental simplicity, portability and minimal microfabrication requirements. | |
dc.identifier.citation | GABRIEL, Ellen F. M. et al. Hydrodynamic injection on electrophoresis microchips using an electronic micropipette. Talanta, (Oxford), v. 162, p. 19-23, 2017. DOI: 10.1016/j.talanta.2016.09.046. Disponível em: https://www.sciencedirect.com/science/article/pii/S0039914016307172?via%3Dihub. Acesso em: 8 ago. 2024. | |
dc.identifier.doi | 10.1016/j.talanta.2016.09.046 | |
dc.identifier.issn | 0039-9140 | |
dc.identifier.issn | e- 1873-3573 | |
dc.identifier.uri | http://repositorio.bc.ufg.br//handle/ri/25869 | |
dc.language.iso | eng | |
dc.publisher.country | Gra-bretanha | |
dc.publisher.department | Instituto de Química - IQ (RMG) | |
dc.rights | Acesso Aberto | |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/4.0/ | |
dc.subject | Automatic dispensing | |
dc.subject | Bias-free sample injection | |
dc.subject | Microfluidic transport | |
dc.subject | Portable instrumentation | |
dc.title | Hydrodynamic injection on electrophoresis microchips using an electronic micropipette | |
dc.type | Artigo |
Arquivos
Pacote Original
1 - 1 de 1
Nenhuma Miniatura disponível
- Nome:
- Artigo - Ellen Flávia Moreira Gabriel - 2017.pdf
- Tamanho:
- 412.83 KB
- Formato:
- Adobe Portable Document Format
Licença do Pacote
1 - 1 de 1
Nenhuma Miniatura disponível
- Nome:
- license.txt
- Tamanho:
- 1.71 KB
- Formato:
- Item-specific license agreed upon to submission
- Descrição: