Precisão da técnica de absorciometria de raios-x de dupla energia na determinação da composição corporal em gatos

dc.creatorBorges, Naida Cristina
dc.creatorVasconcellos, Ricardo Souza
dc.creatorCanola, Júlio Carlos
dc.creatorPaula, Francisco José Albuquerque de
dc.creatorCarciofi, Aulus Cavalieri
dc.creatorPereira, Gener Tadeu
dc.date.accessioned2018-03-16T11:40:48Z
dc.date.available2018-03-16T11:40:48Z
dc.date.issued2008
dc.description.abstractA short-term precision error of the individual subject and the DEXA technique, such as the effect of the repositioning of the cat on the examination table, were established. Four neutered adult cats (BW=4342g) and three females (BW=3459g) were submitted to five repeated scans with and without repositioning between them. Precision was estimated from the mean of the five measurements and expressed by the individual coefficient of variation (CV). The precision error of the technique was estimated by the variance of scan pool (n=35) and expressed in CV for the technique (CVt). The degrees of freedom and confidence intervals were determined to avoid underestimation of precision errors. Bone mineral content (BMC), lean mass (LM), and fat mass (FM) averages were higher (P<0.05) when animals were repositioned. The CVt was significantly higher (P<0.05) for bone mineral density (BMD), LM, and FM when the animals were repositioned. For short-term precision measurements, the repositioning of the animal was important to establish the precision of the technique. The dual energy xray absorptiometry method provided precision for body composition measurements in adult cats.pt_BR
dc.identifier.citationBORGES, N. C.; VASCONCELLOS, R. S.; CANOLA, J. C.; PAULA, F. J. A.; CARCIOFI, A. C.; PEREIRA, G. T. Precisão da técnica de absorciometria de raios-x de dupla energia na determinação da composição corporal em gatos. Arquivo Brasileiro de Medicina Veterinária e Zootecnia, Belo Horizonte, v. 60, n. 1, p. 263-266, 2008.pt_BR
dc.identifier.doi10.1590/S0102-09352008000100037
dc.identifier.issne- 1678-4162
dc.identifier.urihttp://repositorio.bc.ufg.br/handle/ri/14010
dc.language.isoporpt_BR
dc.publisher.countryBrasilpt_BR
dc.publisher.departmentEscola de Veterinária e Zootecnia - EVZ (RG)pt_BR
dc.rightsAcesso Abertopt_BR
dc.subjectCatpt_BR
dc.subjectRepeatabilitypt_BR
dc.subjectDEXApt_BR
dc.titlePrecisão da técnica de absorciometria de raios-x de dupla energia na determinação da composição corporal em gatospt_BR
dc.title.alternativePrecision of dual energy x-ray absorptiometry for body composition measurements in catspt_BR
dc.typeArtigopt_BR

Arquivos

Pacote Original
Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Artigo - Naida Cristina Borges - 2008.pdf
Tamanho:
134.73 KB
Formato:
Adobe Portable Document Format
Licença do Pacote
Agora exibindo 1 - 1 de 1
Nenhuma Miniatura disponível
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: