Utilização do 2-octil-cianoacrilato na ovariectomia de coelhas, comparativamente ao fio de náilon: análise de tempo e alterações macroscópicas
Carregando...
Data
2012-11
Título da Revista
ISSN da Revista
Título de Volume
Editor
Resumo
The development of mass sterilization programmes implies adopting surgical low cost
procedures, fast execution and good post-operative recovery. So, the aim of this
study was to evaluate the practicability of 2-octyl-cyanoacrylate surgical adhesive
used in the haemostasis of ovarian pedicle in rabbits and skin and musculature
juxtaposition as an alternative for nylon suture for surgical castration campaigns in
cats and bitches.The rabbits were divided into two groups of ten each. In the first
group, NG or nylon group, we used a nylon wire for the pedicle haemostasis, skin
and musculature suture. In the second group, OG or 2-octyl-cyanoacrylate group, we
used the 2-octyl-cyanoacrylate surgical adhesive instead of nylon wire. The time
spent was calculated between the beggining (skin incision) and the end of the
procedure (complete skin suture), as well as the time of ligation or pedicle
haemostasis, skin and musculature suture. The surgical wound was inspected in five
animals of each group, during the period of seven and fourteen days after the
surgical procedure. The euthanasia was done in equal numbers of animals during the
period of seven and fourteen days. After the euthanasia, the abdominal cavity was
inspected to search for adhesion presence and inflammatory process of the uterus
and remaining pedicles. In OG, it was verified the occurrence of 60% of adhesions,
10% of evisceration and 20% of free effusion in the cavity in the seventh day of
evaluation. In the fourteenth day of evaluation, it was verified 40% of adhesions, 10%
of liquid in the cavity and no cases of evisceration were observed. In NG, no
occurrence was found in the seventh day and in the fourteenth day, it was found 10%
of adhesions and 10% of cavity effusion. It was concluded that the 2-octylcyanoacrylate
showed to be efficient in vase-occlusion of the ovarian pedicle, in the
juxtaposition of musculature and skin, comparatively to the nylon wire, besides the
high occurrence of adhesions and more time taking for the surgical procedures.
Descrição
Palavras-chave
Adesivo cirúrgico, Castração, Síntese, Sutura, Adhesive surgical, Castration, Synthesis, Suture
Citação
BUENO, Cynthia Marchiori; CEREJO, Sofia de Amorim; MIGUEL, Marina Pacheco; FRANCO, Leandro Guimarães; HONSHO, Cristiane dos Santos. Utilização do 2-octil-cianoacrilato na ovariectomia de coelhas, comparativamente ao fio de náilon: análise de tempo e alterações macroscópicas. Enciclopédia Biosfera, Goiânia, v. 8, n. 15, p. 1657-1671, nov. 2012.