Pioneering evaluation in Brazil of microscope-integrated optical coherence tomography with a three-dimensional digital visualization system during pars plana vitrectomy for the treatment of macular hole

dc.creatorFreitas, Leticia Pinheiro de
dc.creatorMiguel Neto, Jamil
dc.creatorNeves, Laís Lauria
dc.creatorBastos, Thaís Marino de Azeredo
dc.creatorPires, Alexandre Caiado Ferreira
dc.creatorCasella, Antonio Marcelo Barbante
dc.creatorIsaac, David Leonardo Cruvinel
dc.creatorÁvila, Marcos Pereira de
dc.date.accessioned2026-04-23T12:19:27Z
dc.date.available2026-04-23T12:19:27Z
dc.date.issued2025
dc.description.abstractBackground This study aimed to characterize the clinical results and usability of intraoperative optical coherence tomography (iOCT) associated with a digital visualization system in vitreoretinal surgery for macular hole correction. Methods This is a descriptive observational study of patients undergoing vitreoretinal surgery for macular hole at Brazilian Eye Surgery Center in which the digital visualization system associated with iOCT was used. Anatomical and functional results were collected 6 months after surgery. Macular hole closure rates, pre- and post-operative visual acuity were measured in addition to surgeon feedback and the percentage in which the technology allowed intraoperative decision-making. Results 25 eyes of 25 patients were included in the study. The mean preoperative visual acuity was 20/100, ranging from 20/50 to less than 20/400, and postoperative visual acuity was 20/60, ranging from 20/25 to less than 20/400. The time spent with iOCT did not result in surgical delay, as the average time spent was 3.24 extra minutes spent per surgery. Closure of the macular hole was achieved successfully in 92% of cases. In 8% of them surgical success in closing the macular hole was achieved after a new fluid-gas exchange in the office. The surgeon preferred realtime iOCT and, in 4% (1/25) of cases, it influenced the change in surgical technique, preventing unnecessary ILM (Internal Limiting Membrane) peeling after complete removal of the posterior hyaloid and closing the macular hole. In all cases the surgeon reported valid feedback regarding the use of information provided by real-time OCT. This tool was valid for confirming complete ILM peeling in all cases in which it was performed. Finally, iOCT made it possible to identify the appropriate location to begin creating the ILM flap in 2 cases (8%) both of fragile retina; It prevented a new injection of dyes to identify residual ILM in 8% of cases (2/25) and allowed verification of the correct positioning of the pedicled ILM flap over the hole in 16% (4/25) of cases. Therefore, in 36% of cases (9/25) iOCT was essential for the final surgical outcome. Conclusion This study suggests that the use of iOCT integrated with a digital viewing microscope for the treatment of macular holes offers high standard usability and effectiveness for visualizing structures, and impact favorably on decision-making process during pars-plana vitrectomy. These findings suggest that in the near future, expanded use of iOCT could significantly improve tissue management at the vitreomacular interface and improve anatomical and functional results.
dc.identifier.citationFREITAS, Leticia Pinheiro de et al. Pioneering evaluation in Brazil of microscope-integrated optical coherence tomography with a three-dimensional digital visualization system during pars plana vitrectomy for the treatment of macular hole. International Journal of Retina and Vitreous, Berlin, v. 11, e 57, 2025. DOI: 10.1186/s40942-025-00671-8. Disponível em: https://link.springer.com/article/10.1186/s40942-025-00671-8. Acesso em: 22 abr. 2026.
dc.identifier.doi10.1186/s40942-025-00671-8
dc.identifier.issn2056-9920
dc.identifier.urihttps://repositorio.bc.ufg.br//handle/ri/30150
dc.language.isoeng
dc.publisher.countryAlemanha
dc.publisher.departmentFaculdade de Medicina - FM (RMG)
dc.rightsAcesso Aberto
dc.rights.urihttp://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subjectMacular hole
dc.subjectVitrectomy
dc.subjectiOCT
dc.subjectILM peeling
dc.titlePioneering evaluation in Brazil of microscope-integrated optical coherence tomography with a three-dimensional digital visualization system during pars plana vitrectomy for the treatment of macular hole
dc.typeArtigo

Arquivos

Pacote Original

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
Artigo - Leticia Pinheiro de Freitas - 2025.pdf
Tamanho:
3.94 MB
Formato:
Adobe Portable Document Format

Licença do Pacote

Agora exibindo 1 - 1 de 1
Carregando...
Imagem de Miniatura
Nome:
license.txt
Tamanho:
1.71 KB
Formato:
Item-specific license agreed upon to submission
Descrição: