Programa de Pós-graduação em Engenharia Civil
URI Permanente desta comunidade
Navegar
Navegando Programa de Pós-graduação em Engenharia Civil por Por Área do CNPQ "CNPQ::ENGENHARIAS::ENGENHARIA CIVIL::ESTRUTURAS"
Agora exibindo 1 - 17 de 17
Resultados por página
Opções de Ordenação
Item Análise experimental de vigas constituídas de perfis formados a frio com emendas soldadas submetidas à flexão simples(Universidade Federal de Goiás, 2009-09-23) ALMEIDA, Ariovaldo Fernandes de; GOMES, Orlando Ferreira; http://lattes.cnpq.br/3244852416821211The cold-formed steel sheets have been sufficiently used when it is thought of manufacturing a metallic structure with reduced weight. Its use until some time ago in construction was limited to the secondary structures, but, with considerable growth in research involving this type of material together with development of technical standards, made its use a good solution for certain types of light structures. The present work presents considerations on cold-formed steel sheets, the patened steel, processes of welding and the result of experimental tests with beams with composed section of two profiles U constituted with cold-formed steel sheets, manufactured with two types of patened steel produced in Brazil. In some of these beams, welded sections with coated electrode had been used and were made the comparison with the reference beam, where it was possible to study the influence of the process of welding in the ultimate resistance and the ductility of the beam.Item Levantamento das manifestações patológicas em fundações e estruturas nas edificações, com até dez anos de idade, executadas no estado de Goiás(Universidade Federal de Goiás, 2009-11-27) ALVES, Jader Rodrigues; GEYER, André Bortolacci; http://lattes.cnpq.br/0135796530510700The main objective of this research is to proceed to the rising of the indexes, to identify the pathologies and to characterize the constructions that presented occurrences of pathological manifestations in foundations and structures in the constructions executed in the State of Goiás, with age of up to ten years. The researches was classified as documental, considering that, to make possible the accomplishment of the same, the files of Regional Council of Engineering, Architecture and Agronomy of Goiás were analyzed -Crea/GO, with a total sample of 545 reports. It was observed that most of the processes are concerning the last seven years. This Organ was chosen by the fact that all of the technical documents are elaborated by professionals, and, mainly, for Official Organ to be considered. The Method of the Incidence was adopted as methodology recommended for this study observing that in the reports and decisions, elaborated by Crea-GO doesn't be in the number of occurrences of a same pathology and yes only the incidence of the same. The main conclusions of this research were: the main pathological manifestation was found in the foundations repression with a rate of 37.50% followed by collapse with a rate of 22.50%, both in relation to all the pathologies found in the foundation stage, the main pathological manifestation found in stage structure were the cracks with an index of 32.14% compared to all the pathologies found in stage design, regardless of the number executed and the second structural pathological manifestation found in step structure was the structural deformation with an index 19.84% as compared to all the pathologies found in stage design, regardless of the structural piece performed, the building of single-family residential use were the same who had diseases with a rate of 47.50%, followed by residential conference with 35 %, 77.50% of the buildings showed that diseases were carried out by private tutors and, for the buildings surveyed 40% had impairment evaluation of use of buildings facing the diseases occurred in moderate severity, and the rate for high severity was 5%. The disease occurred in low gravity, 45%, most pathological manifestations of both the foundation and structure, occurred in the first year of age of the building. 52.17% in the foundation and concrete structure in 40% of the buildings surveyed, 35% caused damage to neighboring buildings, and 53.49% of this damage occurred within the first year after completion of the work, and the buildings with an area of 5001 m² to 10,000 m² which caused the highest percentage of damage, and the recklessness and incompetence were more technical errors committed by professionals with rates of 32.50% each, followed by neglect of index 22.50 %.Item Influência do tipo de medição na determinação do módulo estático de elasticidade do concreto(Universidade Federal de Goiás, 2011-08-15) ARAÚJO, Suélio da Silva; GEYER, André Bortolacci; http://lattes.cnpq.br/0135796530510700; GUIMARÃES, Gilson N.; lattes.cnpq.br/0060821461126304The knowledge of the compressive strength and static modulus of elasticity is fundamental to the study of deformations of concrete, since deformations can cause cracks that compromise both the structural behavior of the element and serve as an entry to deleterious agents. For purposes of correlating values of compressive strength and static modulus of elasticity of concrete, cylinders were cast with different strengths, different types of strain measurements were taken, different specimen sizes and the loading speed of the testing machine. The specimens were tested at the age of 28 days to determine the compressive strength and static module of elasticity according to ABNT NBR 8522:2008, using different types of strain measurement devices: two mechanical dial indicators, surface bonded strain gages, clip gauges and LVDT (Linear Variable Differential Transducer). Two hundred and fifty eight specimens were cast with dimensions 150 mm x 300 mm and 100 mm x 200 mm using conventional normal strength concrete (NC - Class C30) and high strength concrete (HSC - Class C60). The experimental program was divided into two stages. First the static modulus of elasticity of concrete was measured to evaluate the accuracy of the method using different measuring devices and the accuracy of the method to a loading speed of 0.6 MPa/s. Then, the modulus of elasticity using different deformation measuring devices at a loading speed of 0.3 MPa/s and 0.6 MPa/s was measured. As for concrete NC and HSC, it was found that the specimens 100 mm x 200 mm obtained higher dispersion in relation to 150 mm x 300 mm specimens. In the first stage of the research, 100 mm x 200 mm specimens showed a higher dispersion when using mechanical dial gages and LVDT. The 150 mm x 300 mm NC class C30 specimens showed greater dispersion when using in mechanical dial gages and external strain gages. However, the HSC showed higher dispersion when mechanical dial gages and LVDT were used. In both concretes tested, the mechanical dial gages showed greater dispersion. In the second stage of the research, 150 mm x 300 mm specimens tested at the loading speed of 0.3 MPa/s showed greater dispersion when electrical strain gages and clip gauges were used. The 150 mm x 300 mm specimens tested at loading speed of 0.6 MPa/s showed greater dispersion when electrical strain gages and mechanical dial gages were used.Item Otimização de estruturas reticuladas planas com comportamento geometricamente não linear(Universidade Federal de Goiás, 2006-10-20) ASSIS, Lilian Pureza de; ALMEIDA, Sylvia Regina Mesquita de; http://lattes.cnpq.br/1855764480221018The aim of this work is to present a formulation and corresponding computational implementation for sizing optimization of plane frames and cable-stayed columns considering geometric non liner behavior. The structural analysis is based on the finite element method using the updated lagrangian approach for plane frame and cable elements, which are represented by plane truss elements. The non linear system is solved by the Newton-Raphson method coupled to load increment strategies such as the arch length method and the generalized displacement parameter method, which allow the algorithm to transpose any critical point that happen to appear along the equilibrium path. In the optimization process the design variables are the heights of the crosssection of the frame elements, the objective function represents the volume of the structure and the constraints impose limits to displacements and critical load. Lateral constraints impose limits to the design variables. The finite difference method is used in the sensitivity analysis of the displacement and critical load constraints. The optimization process is carried out using three different optimization strategies: the sequential quadratic programming algorithm; the interior points algorithm; and the branch and bound method. Some numerical experiments are carried out so as to test the analysis and the sensitivity strategies. Numerical experiments are presented to show the validity of the implementation presented in this dissertation.Item Influência da areia artificial oriunda da britagem de rocha granito-gnaisse nas propriedades do concreto convencional no estado fresco e endurecido(Universidade Federal de Goiás, 2007-10-31) CABRAL, Keillon Oliveira; FIGUEIREDO, Enio José Pazini; lattes.cnpq.br/4075543806767323The dissertation is aimed at the study being presented theoretical and experimental verification of the performance of artificial sand come from crushing the rock of granite-gneiss in relation to natural sand. Currently, the sand has artificially low commercial value of the market and is considered a "some kind of piece of marginal material ", whose purpose is not defined and remained stored in the courtyards of the quarries, forming huge piles that cause various environmental impacts. In addition to this, the traditionalism and the lack of information has led to an unwarranted mystification of this material. The methodology used for the tests of the research was based on standardized tests, which attempt to meet the objectives of the dissertation, in addition to enhancing the development of techniques to search for alternative aggregates. This has examined the influence of artificial sand in place of natural sand, with different proportions, and focuses on quality of the concrete in plastic and hardened its phases, taking into account the mechanical, elastic, physicalchemical, environmental and economic. The work was to characterize the material that composed the concrete studied. After this phase, were up corpses-of-proof concrete, using 15 (fifteen) different traits, so that the natural sand was gradually replaced by artificial sand, in proportions of 25%, 50%, 75%, and 100%. For each trait was quantified its rebate, density, air incorporation, resistance to axial compression, traction, deformation module, absorption by immersion, alkali-aggregate reaction and an economic evaluation. It is considered that the main objective of this research has been fully achieved, because it was proven the theoretical feasibility of replacing part or even all, of natural sand by artificial sand in conventionalItem Critérios normativos sobre influência da relação Aw/Af e esbeltez de alma no cálculo da resitência à flexão de vigas esbeltas em elementos de estruturas de aço.(Universidade Federal de Goiás, 2007-10-01) FERNANDES, Rodrigo; BACARJI, Edgar; http://lattes.cnpq.br/2385473000869120; GOMES, Orlando Ferreira; http://lattes.cnpq.br/3244852416821211This work contains a theoretical analysis of the behavior of plate girders. A plate girder has been calculated based on the criteria of the American standard Manual of Steel Construction Load and Resistance Factor Design (AISC, 1994), and checked by the Brazilian standard NBR 8800: Projeto e execução de estruturas de aço de edifícios (método dos estados limites) (ABNT, 1986), the revision project of the Brazilian standard Projeto de Revisão da NBR 8800: Projeto e execução de estruturas de aço e de estruturas mistas aço-concreto de edifícios (ABNT, 2003), the revision project of the Brazilian standard Projeto de Revisão da NBR 8800: Projeto de estruturas de aço e de estruturas mistas de aço e concreto de edifícios (ABNT, 2007) and the European standard Eurocode 3: Design of steel structures Part 1.1: General rules and rules for buildings (CEN, 1992). PFEIL (1989) has calculated a plate girder by using the Brazilian standard NBR 8800/86. The calculated dimension have been checked by the mentioned standards. NARAYANAN (1992 apud OWENS, KNOWLES E DOWLING, 1992) has dimensioned a plate girder by using the British standard BS 5950: Structural use of steelwork in building. Part 1: Code of practice for design in simple and continuous construction: hot rolled sections (BSI, 1990), which has also been checked by the mentioned standards. Furthermore, theoretical analyses related to the calculus of plate girders presented by many authors have been considered. The main goal is to assess the criteria utilized by the standards for the calculus of plate girders. From the obtained results, for the checked girders, by the standards and related theories, a comparative analysis among the utilized criteria by the standards has been made. The reached conclusion is that the Brazilian standard and its revision projects has identical criteria compared to the American standard for the calculus of plate girders. The European standard presents slightly different criteria compared to the American standard; however, both provide close results one compared to another. The theories utilized have also provided close results from those obtained by the standards.Item Resistência à tração de pinos de ancoragem isolados e pré-instalados : Influência da armadura de flexão e de cisalhamento(Universidade Federal de Goiás, 2011-06-27) FONTENELLE, Emmele Gonella; GUIMARÃES, Gilson N.; lattes.cnpq.br/0060821461126304; GOMES, Ronaldo Barros; lattes.cnpq.br/6046088082653028Fastenings inserted in concrete are used in order to allow the introduction of these components in concrete structures, enabling the structural link between metal structures and concrete foundation and between prefabricated components and fixing reinforcement elements. This work will study specifically an anchoring system pre-installed (cast-in-place anchor), consisting of single head studs with square head and subjected to tensile force. Assays were performed in 30 headed studs, using self-compacting concrete with compressive strength in the C-30 class. The main variables are the presence and rate of reinforcement, the arrangement of reinforcement in the blocks, and the influence of both the flexural reinforcement (longitudinal and transverse) and the shear reinforcement (hairpins) on the load capacity of the anchorage. The experimental results were compared with five methods of design found in the literature and show that the flexural einforcement has no effect in increasing the load capacity of the anchorage. The use of a shear reinforcement together with the flexural reinforcement can increase the capacity of the anchor up to 64%. Increasing the distance of the hairpins in relation to the head stud reduces the ultimate load achieved by the anchoring system while the increase in diameter and / or in the number of layers of hairpins can increase the ultimate load.Item INFLUÊNCIA DO TAMANHO DO CORPO DE PROVA NOS RESULTADOS DE ENSAIOS DE MÓDULO DE DEFORMAÇÃO E RESISTÊNCIA À COMPRESSÃO E SUAS CORRELAÇÕES PARA CONCRETOS PRODUZIDOS EM GOIÂNIA - GO(Universidade Federal de Goiás, 2008-10-03) MARTINS, Danilo Gomes; GEYER, André Bortolacci; http://lattes.cnpq.br/0135796530510700Even though the different sizes of cylindrical specimens for tests in concrete are standardized to get the simple compressive strength and the modulus of elasticity, this factor is not usually studied in most researches. So, the goal of this thesis was to evaluate the influence of the size of the specimens in the initial tangent modulus of elasticity (Eci) and in the compressive strength (fc), correlate the values of fc and Eci, and compare the values of modulus of elasticity that were estimated by the equations proposed by the Brazilian code (NBR 6118/2003) and by the American norm (ACI 318/2002). Concretes with three levels of strength were used after 28 days: 25MPa, 30MPa and 40MPa. They were all proportionally mixed with materials of the region and supplied by only one concrete batching plant of Goiânia GO. The tests of compressive strength and initial tangent modulus of elasticity were done in cylindrical specimens of 100 x 200 mm and 150 x 300 mm after 28 days. The samples were collected during the delivery of the concrete in the construction sites. For each truck, ten specimens were molded, five of 100 x 200 mm and five of 150 x 300 mm. Of the 600 specimens that were molded, 240 tests of compressive strength and 360 tests of modulus of elasticity were done. The cure was in a tank with water saturated with limestone. After the tests were done, the statistical analysis of the results was done. The variance analysis (ANOVA) indicated that the size of the specimen exerts influence only on the results of the initial tangent modulus of elasticity (Eci). There is a tendency for the specimens of 100 x 200 mm to show greater results for the modulus of elasticity of the concrete than the specimens of 150 x 300 mm. In the compressive strength, only the level of strength significantly exerted influence on the results. It was also observed that the NBR 6118/2003 overestimates the values of modulus of elasticity of the researched concretes and the results are better adequate to the model proposed by the ACI 318/02.Item Análise experimental de pilares de concreto armado submetidos à flexo-compressão, reforçados com concreto auto-adensável e conectores(Universidade Federal de Goiás, 2009-09-11) NASCIMENTO, Poliana Paula; GOMES, Ronaldo Barros; lattes.cnpq.br/6046088082653028Many problems involving cases of ruins of buildings, bridges, etc., specifically ruin of columns, which are among the most important links in the whole structure, due to project flaw, bad execution or even for the evolution and changing habits. Therefore it has been of fundamental importance researches on the experimental behavior of structures. When conducting a strengthening column using dry with increased self-compacting concrete, it has the drawback of a sudden rupture by peeling the reinforcement. For this, there is a need to study the area of adhesion between substrate and to strengthen and create a way of preparation of this interface area so that the column increases may come into ruin in a ductile flexural as well as in a monolithic column. Thus, it s been developed an experimental study in the School of Civil Engineering, Federal University of Goias, based on analysis of the breaking loads, lateral displacements and deformations of the column of materials for different ways of preparing the surface of the column to be strengthened. The experimental phase of this work was based on testing of nine reinforced concrete columns, which are tested under flexural compression, with eccentricity of 60 mm. Two columns were used as reference columns, one with the original dimensions of the column and the other monolithic concreted in the thickness of a sin reinforced the others received a layer of 35 mm thick concrete selfcompacting in the compressed face. For preparation of the interchange between the two materials, it was proceeded with the scarification and the realization of grooves along this surface, where inserted connectors attached to transverse reinforcement of the columns, varying the position and quantity of the same. It can be concluded that not only quantity, but mainly the location of connectors used in the connection between the substrate and reinforcement, is essential for a good result of resistance and rupture mode. Must be observed a minimum spacing between the connectors strengthening to ensure a more monolithic unit, enabling a ductile rupture occurred as the reference columnItem Punção em lajes lisas de concreto armado com furo adjacente ao pilar e transferência de momento(Universidade Federal de Goiás, 2011-06-17) OLIVEIRA, Diorgenes Carvalho de; MELO, Guilherme Sales Soares de Azevedo; http://lattes.cnpq.br/2099550660739560; GOMES, Ronaldo Barros; lattes.cnpq.br/6046088082653028The structural behavior and the ultimate punching shear resistance of internal reinforced concrete flat slab-column connections, with one hole adjacent to the column, with or without flexural moment transfer of the slab to the column was investigated. Main variables were: the existence whether or not hole, flexural reinforcement layout and ratio, the direction and sense of the moment transferred and the eccentricity of the load (M (moment transferred to column) / V (shear)) ratio at the connection - 0,50 m or 0,25 m. Seven internal slab-column joining were tested and ultimate loads, cracking, deflections, concrete and reinforcement strains were analyzed. The existence of hole adjacent to the smaller column dimension, the hole dimension, flexural reinforcement rate and placing, the variation of relation Mu/Vu in function of the load, and, than, of eccentricity of the load, influenced the slabs behavior and rupture load. These influences were quantified. Test results were compared with the estimations from CEB-FIP/MC1990, EC2/2004, ACI-318:2005 and NBR 6118:2003. ACI and EC2 presented most conservative estimates, although have presented some non conservative estimates. Brazilian NBR, even though being partly based in EC2, presented smaller conservative estimates and more non conservative estimates. A modification on all codes is proposed for taking in account the moment caused by the eccentricity at the critical perimeter for slabs with holes.Item Estudo do uso de barras de transferência de comprimentos reduzidos em pavimentos rígidos de concreto autoadensável(Universidade Federal de Goiás, 2009-06-26) REIS, Fábio Gonçalves dos; GUIMARÃES, Gilson N.; lattes.cnpq.br/0060821461126304The use of concrete pavements in highways is a valuable alternative to obtain a surface with high durability and low maintenance. This type of pavement has the performance compromised by fissures, especially when they occur in the joint with greater vulnerability of the concrete pavement. This work presents a study of the effectiveness of sawed joints in concrete pavements where eleven plates were tested until failure. The variables were: length of circular dowels (200 mm, 300 mm, 400 mm and 500 mm), dowel diameter (10 mm and 16 mm) and type of concrete (conventional and self-compacting). The tests were performed on the concrete plates supported on a base composed of sheets of rubber. A line load was placed on one side of the joint. The test results showed that the use of transfer dowels contributes significantly to the efficiency of the concrete pavements and increasing the length and the diameter of the circular dowels improves efficiency; 10 mm diameter dowels are not compatible with 120 mm thick concrete pavements, but 16 mm dowels bars present good performance; the use of reduced dowel bar lengths below 40 mm is not recommended; pavements with conventional concrete have better performance in the joints due to better aggregate interlocking that the conventional concrete of this search present, when compared the self-compacting concrete; dowels bars with reduced length did not reach yielding, characterizing an incomplete use of steel dowels because the transfer energy its over before the yielding of steel dowelsItem Vigas mistas com laje de concreto e perfis laminados tipo I: análise comparativa do comportamento estrutural entre conectores(Universidade Federal de Goiás, 2010-03-19) RIBEIRO NETO, Juliano Geraldo; GOMES, Orlando Ferreira; http://lattes.cnpq.br/3244852416821211Among the many structural and building systems, it could be highlighted a system that is a mix of steel-concrete that allows the application of their structural and building advantages as whole. When dealing with metal structures, it was noticed some changes regarding the standards of the involved material due to its lack of availability; such measures do not always follow satisfactory structural procedures. This research aims to develop a comparative study about the technical behavior of mixed steel-concrete from three different types of shear connectors (U, U and L cold formed laminated), analyzing their connectors structural behavior when associated with steel beams (Type I rolled and concrete slab). There were three direct shear tests for each type of connector, resulting in a total of nine pieces, and six trials (simply supported composite beams) to evaluate the positive bending moment region. The results indicated that the direct shear behavior between the types of connectors had important and different outcomes; however, they didn t affect significantly the average resistance of the bending mixed beams. Such beams showed considerable results regarding their deflection and deformation performance due to their connectors stiffness.Item Propriedades físicas e mecânicas de argamassa reforçada com fibras do bagaço de cana-de-açúcar (FBC)(Universidade Federal de Goiás, 2010-02-08) SILVA, Janaina Fernandes e; FERREIRA, Regis de Castro; http://lattes.cnpq.br/3206688887219284In this work survey results are reported, it aimed at assessing, through laboratory tests, the exploitation of bagasse-cane (FBC) in composite cementitious (cement mortar, sand and FBC) assessing the physical and mechanical behavior of the material. Problems of chemical incompatibility between the bagasse fibers and cement matrix components have been removed by specific treatments on the CBF, such as washing, boiling, mineralization with chemicals an a mix of cement and water in different combinations. The sugar cane fibers brake down process, used in other studies conducted with the same material, was not necessary, because nowadays the CBF is already broke down in the production process in the ethanol and sugar industry. The fibers were washed and mineralized with inorganic salts (solution of sodium silicate at 5%; aluminum sulfate solution at 3%) and cream of cement (the concentration of 10:1 of water and cement), in order to protect the fiber against the aggressions of the alkaline mortar, trapping organic matter and the residual sugar to avoid interference in the reactions of cement cohesion, reduce the capacity of water absorption. Different concrete mixtures were tested, in order to find one with better compressive strength. The change occurred in the content of CBF added, may be 1.5 or 3.0% by weight of cement and the type of treatment that these fibers were submitted. Were defined traits and body-of-proof molded and compressed manually into cylindrical molds of 5 cm ø and 10 cm in height, corresponding to five combinations of treatments, two ages, two levels of fiber and three replicates, and two types of reference to variations in curing type (moist chamber and the tank with water and lime). Later, the bodiesof- evidence were submitted to tests of compressive traction in diametral compression and water absorption at 7 and 28 days. The best treatments results were: washed CBF + boiled; washed CBF +boiled+cream cement; and washed CBF + boiled + chemicals.Item Avaliação da eficiência do uso de conectores de cisalhamento no reforço de vigas de concreto armado pela face comprimida(Universidade Federal de Goiás, 2011-06-30) SILVA, Paula Miranda da; LISERRE, Andrea Prado Abreu Reis; http://lattes.cnpq.br/9117996162316382A structure is designed to have satisfactory performance during its life given the requirements for which it was designed. When performance becomes unsatisfactory, intervention is needed in order to rehabilitate the structure. Structural rehabilitation is characterized by increasing the structure‟s original load bearing capacity. Of the various existing intervention techniques, this work studies the technique that increases the concrete section by adding more concrete to the compression side and evaluates the effectiveness of shear connectors to bond the new concrete to the base concrete. The increase of the concrete section and the layout of the shear connectors were done along the entire length of the beam. There were two test series. In the first test series, called preliminary tests, the variable studied was the type of connector in order to determine which type ("I", "U" or "AF") would present more efficient results. In the second test series we adopted the connector type "I", which showed the best results from the first series. The variables studied in the second series were the shear connector ratio, the influence of pre-cracking and the presence of confining reinforcement in the new concrete region. The surface treatment used was manual blasting without the use of bonding agents. The test results indicated that the presence of shear connectors type "I", a small ribbed reinforcement bar, prevented the loss of bond between the base concrete and the new concrete, prevented splitting of the new concrete cover which was observed in tests with beams reinforced without the shear connectors. Good results were obtained with respect to increased load bearing capacity of the beams, since even the pre-cracked beams gained strength as well as strength increased in non-cracked ones.Item ESTUDO DE ALVENARIAS E REVESTIMENTOS DE GESSO RECICLADO DESTINADO À HABITAÇÃO POPULAR(Universidade Federal de Goiás, 2008-11-08) SILVA, Renata Moreira de Sá e; TUBINO, Rejane Maria Candiota; http://lattes.cnpq.br/5775852172717383The generation of large quantities of solid waste is a great problem faced by urban areas. Like all building materials, the gypsum plaster is a generator of solid waste. The amount and inadequate waste disposal cause serious environmental, social and economical impacts. This requires the search for quick and effective solutions for its management, through the development of specific programs, which aim to minimize these impacts. This study was developed with the purpose to use waste material of the gypsum industry to built low cost houses with better environmental comfort. Also there were motivations for this study the advantages of gypsum, among them thermal and acoustic insulation, and to help managing municipal waste. Thus, it was studied closing masonry with bricks made by the reuse of gypsum plaster which not have sufficient fluidity to make construction frames anymore. In order to verify which mortar better fit this construction system, two different types of settlement mortars were studied: traditional gypsum paste (GC) and traditional mortar (cement, lime and sand) (AT). The aspects of productivity, cost and strength compression of the constructive system were tested. Coatings were also studied, performed with two types of recycled gypsum: wet recycled gypsum (RU) and dry recycled gypsum (RS), varying their proportions and analyzing the performance of them concerning on workability, cracking, tensile strength and for water absorption and permeability, according to the NIT 140 method proposed by CSTC, from Belgium. In order to verify the thermal and acoustic comfort, a prototype was produced with these new materials. The results showed that the traditional mortar (AT) was the most suitable for the construction of closing masonry made by recycled gypsum, the best internal coating was the 25% paste substituition by wet plaster (RU) and external coating the traditional mortar (AT), 1:1:6 mixture proportion, widely used in constructions. In relation to thermal comfort, there was a better thermal attenuation of recycled gypsum prototype in comparison to a soil cement bricks prototype, also with a good accoustic isolation. The results assured technical and financial viability of using these types of coatings in the construction of low cost housing.Item MODELAGEM NUMÉRICA DE VIGAS DE CONCRETO REFORÇADO COM FIBRAS DE AÇO(Universidade Federal de Goiás, 2006-09-28) SOUZA, Marcel Bruno Silveira e; ARAÚJO, Daniel de Lima; http://lattes.cnpq.br/8801080897723883; PRADO, Ademir Aparecido do; http://lattes.cnpq.br/4118518363912053Item Análise experimental de vigas de seção I compostas de perfis formados a frio com emendas soldadas, submetidas à flexão simples(Universidade Federal de Goiás, 2010-03-19) VIEIRA, Gregório Sandro; GOMES, Orlando Ferreira; http://lattes.cnpq.br/3244852416821211This paper presents an experimental study done in bi-metal beams supported from 3000 mm in length, composed of thin-walled, resulting in a section of the "I". The beams were formed from the welding of the souls of two metal profiles of type U. The variables were the type of profile used, the quantity and positioning of the welded seams. The beams were divided into two groups where the first group used profiles of the "U" and the second group used simple profiles such as "U" stiff. Each group was composed of three beams so that a beam does not receive any amendment, another amendment received a girder high up in the middle of the span, and the third top beam was amended so that the position would result in an amendment pierced. The applied load was set so as to leave the central part of the beams, which served as a region of the present study, working in pure bending. Test results for beams without amendment were compared with the theoretical results and served as a parameter to compare the behavior of these beams, with beams that were amended. Also a comparison was made between the bearing capacity of the two groups of beams. The experiments showed that, by making the proper control of welding there is no problem in making welded seams in the rafters. We also observed that the simple addition of stiffening beams tables promotes a significant increase in the bearing capacity. There was no correlation between failure modes provided theoretically and observed experimentally, thus, further studies are needed to properly analyze the theoretical results with experimental results.