Avaliação por tomografia computadorizada de feixe cônico da posição relativa de mini-implantes instalados com cirurgia não guiada para retenção de overdentures mandibulares

Carregando...
Imagem de Miniatura

Título da Revista

ISSN da Revista

Título de Volume

Editor

Universidade Federal de Goiás

Resumo

Introduction: Parallelism between mini-implants plays a fundamental role in the effectiveness of retentive overdenture systems. Objectives: This cross-sectional study is part of a randomized clinical trial and aimed to evaluate the relative position of mini-implants installed to retain a mandibular overdenture. Furthermore, the aim was to investigate the association of surgical protocol, technical and anatomical factors in the relative position of mini-implants through cone beam computed tomography images. Materials and methods: Tomography scans were analyzed in 73 patients who received four single-body mini-implants. Drilling was performed with a 1.6mm needle drill and 2.2mm Pilot Drill, according to the patient's bone density and the orientation of the surgical guide. Post-insertion CBCT images were analyzed using E-Vol-DX software with bone tissue removal filters. Divergence angles between implants and between the implants and the overdenture insertion path were measured using CliniView 10.2.6 software. Results: The divergence angles between the implants ranged from 0° to 22.3° (mean=4.2; SD=3.7) and from 0° to 26.2° (mean=5.3; SD=4 ,1) in the lateral and frontal projections, respectively (p<0.001). Only 1 (0.2%) and 3 (0.7%) of the measurements were greater than 20° in the lateral and frontal views, respectively. The average angulations between the implant and the overdenture insertion path were 9.3° (SD=7.5) and 4.0° (SD=2.9) for the lateral and frontal views, respectively (p<0.001). Regression analyzes showed a significant association between implant divergence and frontal view projection (p<0.001), greater distance between paired implants (p=0.017), surgical protocol (p=0.002), greater insertion torque final (p=0.011) and deeper preparation with the needle drill (p<0.001). The position of the implants was also associated with divergence in relation to the insertion path (p<0.05) Conclusions: The results showed that the mini-implants in this study were placed with low divergence angles and satisfactory parallelism. Factors such as shorter distances between implants, higher bone density and a flapless surgical approach have contributed positively to improving the parallelism of mini-implants.

Descrição

Citação

MOURA NETO, L. O. Avaliação por tomografia computadorizada de feixe cônico da posição relativa de mini-implantes instalados com cirurgia não guiada para retenção de overdentures mandibulares. 2024. 66 f. Dissertação (Mestrado em Odontologia) - Faculdade de Odontologia, Universidade Federal de Goiás, Goiânia, 2024.