Efeito do tipo de cimento e de materiais cimentícios suplementares na resistividade elétrica superficial do concreto
Carregando...
Data
Título da Revista
ISSN da Revista
Título de Volume
Editor
Resumo
Non-destructive testing is an important inspection and monitoring tool for
reinforced concrete structures. Among them, surface electrical resistivity is a
versatile and easy-to-obtain durability indicator. This article aims to evaluate
the influence of the type of cement (CP II-Z, CP IV and CP V-ARI) and
supplementary cementitious materials - SCM (silica fume, rice husk silica,
metakaolin and fly ash) on surface electrical resistivity of concrete, using
Wenner method, over a year. Additionally, correlations were carried out
between resistivity and other properties, such as compressive strength, water
absorption and rapid chloride permeability test - RCPT. The results indicated
that the resistivity was significantly influenced by the type of cement and MCS
and by the age of the samples. The magnitude of the resistivity of the mixtures
with MCS exceeded that of the reference mixture. Furthermore, the resistivity
showed correlations with R² above 0.70 with the compressive strength of
concretes with SCM and with the passing electrical load of the RCPT test.
Descrição
Citação
MEDEIROS, Marcelo Henrique Farias de et al. Efeito do tipo de cimento e de materiais cimentícios suplementares na resistividade elétrica superficial do concreto. Ambiente Construído, Porto Alegre, v. 23, e140952, 2025. DOI: 10.1590/s1678-86212025000100874. Disponível em: https://www.scielo.br/j/ac/a/Cz644jqmRSQ7qMfWWVS3KBR/?lang=pt. Acesso em: 22 jun. 2026.